Skip to main content

A new strategy for volumetric-modulated arc therapy planning using AutoPlanning based multicriteria optimization for nasopharyngeal carcinoma

Abstract

Background

A new strategy for making the appropriate choice of the representative optimization parameters in planning processes and accurate selection criteria during Pareto surface navigation for general multicriteria optimization (MCO) was recommended in the study. The purpose was to combine both benefits of AutoPlanning optimization and MCO (APMCO) for achieving an individual volumetric-modulated arc therapy (VMAT) plan according to the clinically achieved patient-specific tradeoff among conflicting priorities. The preclinical investigation of this optimization approach for nasopharyngeal carcinoma (NPC) radiotherapy was performed and compared to general MCO VMAT.

Methods

A total of 60 NPC patients with various stages were enrolled in this study. General MCO and APMCO plans were generated for each patient on the treatment planning system. The differences between two planning schemes were evaluated and compared.

Results

All plans were capable of achieving the prescription requirement. The planning target volume coverage and conformation number were remarkably similar between general MCO and APMCO plans. There were no significant differences in most of organs at risk (OARs) sparing. However, in APMCO plans, relatively remarkable decreases were observed in the mean dose (Dmean) to the glottic larynx and pharyngeal constrictor muscles. The reductions of average Dmean to the two OARs were 10.5% (p < 0.0001) and 8.4% (p < 0.0001), respectively. APMCO technique was found to increase the planning time for an average of approximately 5 h and did not lead to a significant increase of monitor units compared to general MCO.

Conclusions

The potential of the APMCO strategy is best realized with a clinical implementation that exploits individual generation of Pareto surface representations without manual interaction. It also assists physicians to ensure navigation in a more efficient and straightforward manner.

Background

Volumetric-modulated arc therapy (VMAT) has experienced a rapid and widespread clinical application due to the similar or superior plan quality to the fixed field intensity modulated radiation therapy [1,2,3]. However, a challenging problem for VMAT is that the optimal treatment plan generally depends on the planner’s devoted time and experience [4] to translate the clinical goals into optimization parameters accounting for the relation among three competing priorities: planning target volume (PTV) coverage, PTV dose homogeneity, and sparing of the adjacent organs at risk (OARs). More concern seems to be attracted especially for the complicated head and neck cancer, such as nasopharyngeal carcinoma (NPC) where multiple PTV dose levels are defined close to OARs. Recently, multicriteria optimization (MCO) techniques have been introduced into VMAT planning [5,6,7,8,9]. The rationale of multicriteria VMAT optimization is to first efficiently explore a Pareto-optimal tradeoff between conflicting priorities in the fluence domain, and second fine-tune the tradeoff with respect to deliverable linear accelerator settings and final dose calculated.

In principle, MCO enables planners to determine a best-possible compromise using an ideal Pareto surface. Even with MCO, there remains a manual selection bias owing to variations in the management of clinical tradeoffs. In general, the choice of optimization parameters in planning processes [10,11,12,13] and selection criteria during Pareto surface navigation [14, 15] may yield different tradeoffs in MCO. Different solutions may produce tradeoffs among different choices. Without the patient-specific choices, MCO planning also needs a manual trial-and-error process similar to traditional inverse planning. In many situations, subjectivity in which tradeoffs are made results in suboptimal plans being delivered in the clinical routine practice, resulting in worse patient outcomes. The great concern and difficulty in MCO planning is how to determine the representative optimization parameters and accurate selection criteria for the optimal Pareto plan. Because of the difficulty in lacking the accurate tradeoff information, there are no guarantees on deriving the optimality of solutions after the numerous continuing searches. Although this problem has been addressed by a number of research groups over the past 10 years [16,17,18,19,20], there is still no good solution for automatically finding the optimal choice.

Recently, AutoPlanning (AP) approach has been incorporated in clinical processes to improve plan quality and efficiency [21, 22]. The concept is largely to capture the steps that an experienced planner would take and then simulate them for a new patient. AP employs an iterative algorithm approach to reach and potentially surpass clinical goals that planners defined. Individual optimization goals, constraints and weights are automatically added and adjusted during AP. The optimizer will run multiple times with adjustments being made during and between optimization runs. Additionally, AP adjusts the priority of clinical goals based on the probability of being achieved. Although AP appears to have difficulty in determining a Pareto-optimal compromise, it would be a fully automated planning process to efficiently explore a patient-specific tradeoff.

The quality of plans generated by the MCO approach was evaluated by comparison with benchmark plans generated by the conventional manual approach [9, 15, 20]. MCO has proven to be an efficient approach, both in terms of dosimetric quality and planning efficiency. A notable difference to previous work is that we focused on recommending a new strategy for making the appropriate choice of the representative optimization parameters in planning processes and accurate selection criteria during Pareto surface navigation for general MCO. The purpose of this study was to combine both benefits of AP optimization and MCO (APMCO) for achieving an individual VMAT plan according to the clinically achieved patient-specific tradeoff among conflicting priorities. The preclinical investigation of this optimization approach for NPC radiotherapy was performed and compared to general MCO VMAT.

Methods

Patient selection and contouring

Considering a heterogeneous patient collective, a total of 60 NPC patients treated with VMAT between January 2016 and September 2017 were consecutively enrolled in this study. All patients were immobilized in the supine position with a head, neck and shoulder thermoplastic mask. The patients’ characteristics are presented in Table 1. None of the patients had received prior radiotherapy, and all were free of distant metastases. Computed tomography with a 3 mm slice thickness of the head and neck region was obtained for each patient and imported to the treatment planning system (TPS). According to the Radiation Therapy Oncology Group (RTOG) protocols 0225 and 0615, the same attending physician delineated the target area and OARs for all patients. The target area included three clinical target volumes (CTVs): CTV70, defined as 70 Gy radiation to the nasopharyngeal gross tumor and lymphadenopathy; CTV59.4, defined as 59.4 Gy radiation to the high-risk lymphatic regions; and CTV54, defined as 54 Gy radiation to the low-risk regions. The PTV provided a 3 mm margin around the CTV to compensate for the variability of treatment set up and internal organ motion, except for the situation that the CTV was adjacent to the brain stem, where the margin could be as small as 1 mm. The OARs included the brain stem, spinal cord, parotid glands, optic nerves, chiasm, temporal lobes, oral cavity, lenses, glottic larynx, submandibular glands and pharyngeal constrictor muscles.

Table 1 Patient characteristics (N = 60)

Dose prescription and treatment planning

The commonly used simultaneously integrated boost technique was adopted at our institution. The dose prescribed to PTV70 was 2.12 Gy per fraction, to PTV59.4 was 1.8 Gy per fraction and PTV54 was 1.64 Gy per fraction in 33 fractions, respectively. We adopted the Varian Trilogy linear accelerator (Varian Medical Systems, Palo Alto, CA, USA) to compare general MCO VMAT to APMCO VMAT, and 6MV photon beams were applied to all plans. The treatment goals were that 100% of the prescribed dose would cover 95% of the PTV received three dose levels, and the maximum dose would not exceed 110%. The dose-volume constraints to critical OARs from the RTOG protocols 0225 and 0615 are described in Table 2. According to the International Commission on Radiation Units and Measurements report 83, the near minimum dose (D98%) was the dose to 98% of the structure, the near maximum dose (D2%) was defined to be the dose to 2% of the structure and the mean dose (Dmean) was the mean dose to the structure. Regarding the OARs, D2% to the brain stem, the spinal cord, the optic nerves and the chiasm was set as 54 Gy, 45 Gy, 54 Gy, and 54 Gy, respectively. In addition, at least one of the parotid glands should receive a Dmean of no more than 26 Gy, or at least 50% of one gland should receive < 30 Gy.

Table 2 The dose-volume constraints to critical OARs used in VMAT optimization

The VMAT plans, described earlier [23], were generated using two complete arcs plus one partial arc (moving from gantry angle of 240° to 120° in the clockwise direction). The collimator angle was set at 20° for all plans to minimize the cumulative effects of interleaf transmission and the tongue-and-groove effect. The 3° was set as a spacing unit in this study for the compromise between the number of optimizable multileaf collimator leaf positions and calculation time. The same Trilogy linear accelerator data was commissioned in the Pinnacle TPS (Version 9.10, Philips Radiation Oncology Systems, Fitchburg, WI) and RayStation TPS (Version 3.0, RaySearch Laboratories AB, Stockholm, Sweden). The dose differences between the two systems were verified within 1.5% during the commission process [24].

Description of AP

A new optimizer, AP, was introduced in Pinnacle TPS. The AP module simplifies the planning process through the use of templates (derived regions of interest, placement of points of interest, prescriptions, beam geometries, settings, and optimization options and prioritized optimization goals), and automatic optimization tuning algorithm (called the AP engine). A single selection creates a new plan based on the templates and runs the AP engine. The AP engine maps the prioritized optimization goals defined in the templates to optimization objectives. Multiple optimization loops are performed that iteratively adjust the optimization parameters to meet the goals and further drive down OAR sparing with minimal compromise to the PTV coverage. It is achieved by using parameters specific to driving down OAR dose to the point that it significantly affects PTV coverage and separate parameters to achieve the planning goals. PTV conformity and uniformity is automatically controlled by particular system-generated structures. It is similar to the process defined in the study by Xhaferllari et al. [21]. OAR dose is controlled by normal tissue structures. All the optimization parameters (dose and weight) are adjusted using a proprietary approach. In brief, the AP software is analogous to experienced planners drawing new structures and adjusting parameters to make inverse plans more clinically desirable.

Description of MCO and clinical workflow

MCO has been commercialized in RayStation TPS. The whole workflow of general MCO VMAT and APMCO VMAT treatment is schematically presented in Fig. 1. There are mainly three stages in general MCO planning process: in the first stage, the TPS generates Pareto-optimal plans according to the typical dose-volume constraints input as the optimization parameters for the multicriterial planning problem and stores them in a database. In the planning process, no sufficient quantitative judgments are used to reduce adverse effects that can jeopardize survival advantages other than a set of dose-volume constraints. The most common constraints have typically been determined using the population-based constraints such as RTOG protocol recommendations. In the second stage, the physician interactively explores the Pareto surface and decides for the best-possible compromise for the patient, depending on the individual experience. In the last stage, the deliverable plan is finalized by multileaf collimator sequencing and final dose calculation. The Pareto surface approximation is calculated by optimizing various weighted sums of the objective cost functions. For N functions at least N + 1 plans in the Pareto database are calculated [10], and the maximum plan number is given by the TPS with 4 N (default usage for the remarkable performance in this study).

Fig. 1
figure 1

The workflow of general MCO VMAT and APMCO VMAT treatment

The overall workflow of APMCO VMAT is quite similar in general. The major differences were the optimization parameters and selection criteria. For general MCO, the optimization parameters and selection criteria were directly from the population-based dose constraints. For APMCO, the population-based dose constraints as the initial optimization parameters were input to Pinnacle for AP optimization. After AP progress, the individual AP dose-volume histograms (DVHs) as the representative optimization parameters were used as the input for MCO in RayStation. During final plan selection in the navigation step, APMCO can make the physician who is confronted with the full range of alternative choices ensure navigation in a more efficient and straightforward manner according to the accurate selection criteria obtained from AP instead of the individual experience.

Dose comparisons

Plan comparisons were performed between general MCO and APMCO plans. In order to minimize the influence of the inter-operator variation, the same planner and physician adopting the same plan criteria were engaged in this study. DVHs were calculated for all plans. For PTVs, D98% and D2%were compared. The conformity of the PTV dose was evaluated by the conformation number (CN) according to the following eq. (1):

$$ \mathrm{CN}=\frac{{{\mathrm{PTV}}^2}_{\mathrm{ref}}}{{\mathrm{V}}_{\mathrm{PTV}}\times {\mathrm{V}}_{\mathrm{ref}}}, $$
(1)

where PTVref represented the volume receiving the prescription dose in PTV, VPTV stood for the volume of the PTV, and Vref was the volume that received the prescribed dose. For OARs, D2% was applied to evaluate the dose to serial organs, such as the brain stem, spinal cord, optic nerves, chiasm and temporal lobes, and Dmean to parallel organs, such as the parotid glands, oral cavity (excluding PTV’s), glottic larynx, submandibular glands and pharyngeal constrictor muscles. For parotid glands, the percent volume of each parotid that received 30 Gy (V30) was also evaluated and compared. The plan difference was facilitated by defining the relative OAR dose deduction (δ) according to the following eq. (2):

$$ \updelta =\frac{{\mathrm{P}}_{GeneralMCO}\hbox{-} {\mathrm{P}}_{\mathrm{APMCO}}}{{\mathrm{P}}_{GeneralMCO}}\times 100, $$
(2)

where P refers to the dose (Gy).

The number of monitor units (MUs) for all plans and planning time including the time spent for optimization and dose calculation until the final plan was produced were also reported.

Statistical analysis

Statistical analysis was performed to compare the dosimetric differences between general MCO and APMCO plans. The normal distribution of variables was firstly checked with the Kolmogorov-Smirnov test. Paired t-tests were used to compare the different parameters. A p-value < 0.05 was considered statistically significant. All statistical analyses were performed with IBM-SPSS statistics, version 19 (SPSS Inc., Chicago, IL).

Results

PTV coverage and CN

The dose distributions for one representative NPC patient on coronal planes of general MCO and APMCO plans are shown in Fig. 2a–b, respectively. Table 3 presents the detailed statistical analysis of PTVs, which are averaged over 60 patients. All plans were capable of achieving the prescription requirement. There were almost no statistically significant differences between general MCO and APMCO plans in terms of PTV70, PTV59.4, PTV54 coverage and CN. It clearly showed that the PTV dose distributions were essentially equivalent between the two plan types.

Fig. 2
figure 2

The coronal dose distributions for a general MCO VMAT and b APMCO VMAT are shown for one representative patient. c displays the dose difference between (a) and (b)

Table 3 Summary of the dosimetric parameters from the investigated techniques of PTVs, OARs and MUs

OARs sparing

Figure 2c displays the dose differences between Fig. 2a, and Fig. 2b. Fig. 3 shows the mean DVHs of all structures. The distributions of all DVH metrics were sufficiently similar to normal distributions. The major dose differences occurred in the glottic larynx and pharyngeal constrictor muscles. Table 3 also summarizes the dosimetric parameters from the investigated techniques of OARs. There were no significant differences in most of OARs sparing. However, in APMCO plans, relatively remarkable decreases were observed in Dmean to the glottic larynx and pharyngeal constrictor muscles. The reductions of average Dmean to the two OARs were 10.5% (p < 0.0001) and 8.4% (p < 0.0001), respectively. Figure 4 illustrates the effect of APMCO implementation on glottic larynx and pharyngeal constrictor muscles dose. The results suggested that APMCO technique could more effectively protect the glottic larynx and pharyngeal constrictor muscles.

Fig. 3
figure 3

The mean DVHs for PTVs and OARs comparing general MCO (solid lines) to APMCO (dotted lines). a PTV70, PTV59.4 and PTV54 b Brain stem, spinal cord, optic nerves, chiasm and parotid glands c Lens and temporal lobes d Oral cavity (excluding PTV’s), glottic larynx, submandibular glands and pharyngeal constrictor muscles

Fig. 4
figure 4

The box plot depicting the effect of APMCO implementation on glottic larynx and pharyngeal constrictor muscles dose. δ means the relative OAR mean dose deduction. The center line inside box is the median value. The box represents the interquartile range (IQR) from 25% quartile to 75% quartile. The cross indicates the outlier which is defined as the points more than 1.5 times IQR away from the box edge. The solid lines connect the box with the most extreme values which are not outlier

Planning efficiency and MUs

Multiple PTVs and OARs that needed to be balanced in NPC treatment resulted in a time-consuming process. An average of approximately 5 h was required to create each MCO plan. APMCO technique significantly increased the planning time. Additional average of approximately 5 h was required to create each AP plan. The mean number of MUs for APMCO plans was 505.6 compared to 510.5 for general MCO ones (p > 0.05) (Table 3). The use of APMCO did not lead to a significant increase of MUs.

Discussion

In this study, a new optimization approach was developed for VMAT planning. We demonstrated the feasibility of implementing APMCO to assist VMAT. NPC chosen for the analysis represented an ideal platform for this study. Besides its relatively high incidence in Southeast Asia and China, there are multiple PTVs and a great deal of individual radiosensitive OARs that need to be balanced, testing APMCO performance in a demanding clinical scenario. Our results showed that APMCO plans maintained similar PTV coverage and CN, and similar or superior OARs sparing to general MCO ones. As more agents are tested in combination with radiation in attempts to improve the efficacy of chemoradiation, it is highly desirable to explore new strategies for NPC patients that will decrease radiation-specific adverse effects. The quantitative analysis of normal tissue effects in the clinic project [25] reviewed several dose-response studies for laryngeal edema, vocal dysfunction and dysphagia. It found that the probability of these adverse effects increased significantly with the dose to the glottic larynx and pharyngeal constrictor muscles. In our study, the relevantly improved sparing of the two OARs was achieved after implementing APMCO without compromising PTV coverage, homogeneity, and sparing of the rest of OARs. It was suggested that the dose reduction in these two tissues did not result from the redistribution of the dose to PTVs and other OARs, but rather from the utilization of APMCO. Furthermore, additional reduction of potential treatment adverse effects may offer the opportunity to effectively improve the quality of life.

In the planning process, the idea underlying the MCO formulation is that each anatomical structure is assigned one or several parameters. Therefore, even with MCO the optimization results depend heavily on the optimization parameters. This is an open question as to which sets of choices best achieve the appropriate balance of dose distribution. Craft et al. [10] demonstrated that the resulting generation of the Pareto surface was sensitive to the used parameters particularly for some parallel OARs, where D2% and Dmean were not correlated. Therefore, a key challenge in MCO is to define the patient-specific parameters that will directly affect the Pareto surface generation. Various solutions have been proposed to assist planners to efficiently balance clinical tradeoffs and decide the clinically achievable plans, such as knowledge-based planning (KBP) [26,28,29,30,31,32,33,34,35,36,37] and AP [21, 22]. KBP has proven to be an efficient tool for significantly improving planning efficiency and stability. More importantly, adoption of KBP led to varying degrees of improved OARs sparing for head and neck cancer patients, such as parotid glands, oral cavity, glottic larynx and cochlea [32, 33]. A key pre-requisite of KBP is to compile a sufficiently large number of high quality plans to build a DVH estimation model. One disadvantage is the range of patient geometries in the model, which still may not represent the full diversity of NPC cases due to individual differences. The estimations and statements about the accuracy of the model may be compromised to a certain extent when applying the model to those patients whose geometry falls outside the range of the constituent plans in the model. Another disadvantage is that the performance of KBP mainly depends on the quality of model. Suboptimal plans in the model may degrade results with the KBP approach. Furthermore, the predicted goals are directly applied to TPS’s optimizer, and no further adjustments are made during optimization. Unlike KBP, AP relies on the optimization algorithm itself to iteratively adjust planners’ pre-set, PTVs/OARs DVH objectives during optimization to meet or exceed coverage/sparing goals. In APMCO, planners are free to use the valuable knowledge from AP and to adjust quickly and efficiently the allowable minimum dose to the OARs with confidence that the dose to the target and other tissues will remain uncompromised, thus greatly reducing the time-consuming iteration loops.

A wide range of mathematically optimal alternatives are available during navigation. As a result, it suggests a paradigm shift in the decision making process during which the physician gets an insight of the solution space by navigating through alternative compromises. Voet et al. [38] used the prioritized optimization, resulting in one treatment plan only, and not requiring manual Pareto surface navigation. The in-house-developed algorithm is promising but not yet commercially available. Just as our experience in using MCO, navigating to the clinically optimal plan from the Pareto surface plan database is equally critical to achieving high quality plans. It involves higher-level information which is often non-technical, qualitative and experience-driven. The OARs sparing in MCO plans also reflects the ability of physicians to prioritize a lot of different structures during the final plan selection in the navigation step. For example, the routine clinical practice is that under-dosing to PTVs and critical OARs placed in high priority level will be focused on and unspecified tissues tend to be less important. Appreciable variation exists in the navigation step, depending on the experience of individual physicians. Due to lacking in the knowledge of such a wide variety of tradeoff solutions, the decision making for how to cope with the problem is rather demanding especially for physicians who have few experiences during navigation. Although physicians can choose a scalarized objective and find the resulting solution, there are no guarantees that they can derive the optimal solution every time even when experienced ones are involved. However, once the individual and accurate tradeoff information is obtained from AP, no matter whether physicians are experienced or not can ensure navigation in a more efficient and straightforward manner.

The Pareto surface plan database is very large-dimensional since NPC has multiple PTVs and many individual OARs to consider. Reducing the dimensionality of the database is a very important consideration. Kierkels et al. [39] demonstrated that the application of clinically validated multivariable normal tissue complication probability (NTCP) models (including multiple dose parameters and prognostic clinical factors) in the planning process facilitated the dose distributions and corresponding NTCP-estimates in head and neck cancer patients. It may be more appropriate, especially in a multicriteria setting, to reduce the number of currently used tradeoff objectives to a few NTCP-based objectives, simplifying the navigation process. This is a promising area and definitely more computationally faster objective-reduction techniques are needed for the purpose.

One important limitation for MCO is that the Pareto surface generation step is computationally costly. Clinical constraints of time and effort also should be kept a close eye on. To our knowledge, the time expense of computing a modest number of fluence-based plans can exceed 5 h for complicated NPC cases. Furthermore, APMCO VMAT required additional average of 5 h compared to general MCO VMAT. The search for AP plans is not in a time-efficient manner since the optimizer will run multiple times with adjustments of optimization parameters. This situation becomes especially challenging in triple-arc VMAT plans. The clinically infeasible planning time seems to severely limit the usability. Special caution should be taken when APMCO is applied in the clinical practice. Fortunately, most of the planning time is not “active planning” time which does not require active manual intervention. Improvements in computer architecture, e.g. by calculation on the graphics processing unit, or generation of plans in parallel over multiple workstations might drastically reduce the planning time. For early-stage NPC cases, VMAT plans generated using only one arc may greatly reduce the planning time and seem to be well tolerable. Another limitation is that AP optimization and MCO are entirely two separate processes. An ideal procedure is to incorporate simultaneously AP into the MCO framework. APMCO should be more usable in practice in the future. The last limitation is that we just focused on recommending a new strategy for MCO in this study. Further studies are therefore needed to go into the mathematical details of the optimization algorithm. In principal, the new optimization approach can also be used for other site tumors such as thorax, abdomen, etc.

Conclusion

A new strategy for making the appropriate choice of the representative optimization parameters in planning processes and accurate selection criteria during Pareto surface navigation for general MCO was recommended. The APMCO approach combines both benefits of AP optimization and MCO for achieving an individual VMAT plan according to the patient-specific tradeoff among conflicting priorities at a cost of increased planning time which does not require active manual intervention. The potential of the APMCO strategy is best realized with a clinical implementation that exploits individual generation of Pareto surface representations without manual interaction. It also assists physicians to ensure navigation in a more efficient and straightforward manner.

Abbreviations

AP:

AutoPlanning

APMCO:

AP optimization and MCO

CN:

Conformation number

CTV:

Clinical target volumes

D2% :

Near maximum dose

D98% :

Near minimum dose

Dmean :

Mean dose

DVH:

Dose-volume histogram

KBP:

Knowledge-based planning

MCO:

Multicriteria optimization

MU:

Monitor unit

NPC:

Nasopharyngeal carcinoma

NTCP:

Normal tissue complication probability

OAR:

Organ at risk

PTV:

Planning target volume

RTOG:

Radiation Therapy Oncology Group

TPS:

Treatment planning system

V30 :

The percent of volume that received 30Gy

VMAT:

Volumetric-modulated arc therapy

δ:

The relative dose deduction

References

  1. Yu CX, Tang G. Intensity-modulated arc therapy: principles, technologies and clinical implementation. Phys Med Biol. 2011;56:R31–54.

    Article  PubMed  Google Scholar 

  2. Verbakel WF, Cuijpers JP, Hoffmans D, Bieker M, Slotman BJ, Senan S. Volumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study. Int J Radiat Oncol Biol Phys. 2009;74:252–9.

    Article  PubMed  Google Scholar 

  3. Yoo S, Wu QJ, Lee WR, Yin FF. Radiotherapy treatment plans with RapidArc for prostate Cancer involving seminal vesicles and lymph nodes. Int J Radiat Oncol Biol Phys. 2010;76:935–42.

    Article  PubMed  Google Scholar 

  4. Bohsung J, Gillis S, Arrans R, Bakai A, De Wagter C, Knöös T, et al. IMRT treatment planning: a comparative inter-system and inter-Centre planning exercise of the ESTRO QUASIMODO group. Radiother Oncol. 2005;76:354–61.

    Article  PubMed  Google Scholar 

  5. Pardo-montero J, Fenwick JD. An approach to multiobjective optimization of rotational therapy. Med Phys. 2009;36:3292–303.

    Article  PubMed  Google Scholar 

  6. Pardo-Montero J, Fenwick JD. An approach to multiobjective optimization of rotational therapy. II. Pareto optimal surfaces and linear combinations of modulated blocked arcs for a prostate geometry. Med Phys. 2010;37:2606–16.

    Article  PubMed  Google Scholar 

  7. Craft D, McQuaid D, Wala J, Chen W, Salari E, Bortfeld T. Multicriteria VMAT optimization. Med Phys. 2012;39:686–96.

    Article  PubMed  PubMed Central  Google Scholar 

  8. Bokrantz R. Multicriteria optimization for volumetric-modulated arc therapy by decomposition into a fluence-based relaxation and a segment weight-based restriction. Med Phys. 2012;39:6712–25.

    Article  PubMed  Google Scholar 

  9. Ghandour S, Matzinger O, Pachoud M. Volumetric-modulated arc therapy planning using multicriteria optimization for localized prostate cancer. J Appl Clin Med Phys. 2015;16:5410.

    Article  PubMed  Google Scholar 

  10. Craft D, Halabi T, Bortfeld T. Exploration of tradeoffs in intensity-modulated radiotherapy. Phys Med Biol. 2005;50:5857–68.

    Article  PubMed  Google Scholar 

  11. Breedveld S, Storchi PR, Keijzer M, Heemink AW, Heijmen BJ. A novel approach to multi-criteria inverse planning for IMRT. Phys Med Biol. 2007;52:6339–53.

    Article  PubMed  Google Scholar 

  12. Thieke C, Küfer KH, Monz M, Scherrer A, Alonso F, Oelfke U, et al. A new concept for interactive radiotherapy planning with multicriteria optimization: first clinical evaluation. Radiother Oncol. 2007;85:292–8.

    Article  PubMed  Google Scholar 

  13. Holdsworth C, Kim M, Liao J, Phillips M. The use of a multiobjective evolutionary algorithm to increase flexibility in the search for better IMRT plans. Med Phys. 2012;39:2261–74.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Monz M, Küfer KH, Bortfeld TR, Thieke C. Pareto navigation: algorithmic foundation of interactive multi-criteria IMRT planning. Phys Med Biol. 2008;53:985–98.

    Article  PubMed  CAS  Google Scholar 

  15. Craft DL, Hong TS, Shih HA, Bortfeld TR. Improved planning time and plan quality through multicriteria optimization for intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys. 2012;82:e83–90.

    Article  PubMed  Google Scholar 

  16. Lahanas M, Schreibmann E, Baltas D. Multiobjective inverse planning for intensity modulated radiotherapy with constraint-free gradient-based optimization algorithms. Phys Med Biol. 2003;48:2843–71.

    Article  PubMed  Google Scholar 

  17. Craft DL, Halabi TF, Shih HA, Bortfeld TR. Approximating convex pareto surfaces in multiobjective radiotherapy planning. Med Phys. 2006;33:3399–407.

    Article  PubMed  Google Scholar 

  18. Craft D, Halabi T, Shih HA, Bortfeld T. An approach for practical multiobjective IMRT treatment planning. Int J Radiat Oncol Biol Phys. 2007;69:1600–7.

    Article  PubMed  Google Scholar 

  19. Jee KW, McShan DL, Fraass BA. Lexicographic ordering: intuitive multicriteria optimization for IMRT. Phys Med Biol. 2007;52:1845–61.

    Article  PubMed  Google Scholar 

  20. Hong TS, Craft DL, Carlsson F, Bortfeld TR. Multicriteria optimization in intensity-modulated radiation therapy treatment planning for locally advanced Cancer of the pancreatic head. Int J Radiat Oncol Biol Phys. 2008;72:1208–14.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Xhaferllari I, Wong E, Bzdusek K, Lock M, Chen J. Automated IMRT planning with regional optimization using planning scripts. J Appl Clin Med Phys. 2013;14:4052.

    Article  PubMed  Google Scholar 

  22. Krayenbuehl J, Norton I, Studer G, Guckenberger M. Evaluation of an automated knowledge based treatment planning system for head and neck. Radiat Oncol. 2015;10:226.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  23. Kan MW, Wong W, Leung LH, Yu PK, So RW, Cheng AC. A comprehensive dosimetric evaluation of using RapidArc volumetric-modulated arc therapy for the treatment of early-stage nasopharyngeal carcinoma. J Appl Clin Med Phys. 2012;13:3887.

    Article  PubMed  Google Scholar 

  24. Hu W, Wang J, Li G, Peng J, Lu S, Zhang Z. Investigation of plan quality between RapidArc and IMRT for gastric cancer based on a novel beam angle and multicriteria optimization technique. Radiother Oncol. 2014;111:144–7.

    Article  PubMed  Google Scholar 

  25. Rancati T, Schwarz M, Allen AM, Feng F, Popovtzer A, Mittal B, et al. Radiation dose-volume effects in the larynx and pharynx. Int J Radiat Oncol biol Phys. 2010;76 Suppl 3:S64-9.Int J Radiat Oncol Biol Phys 2010;76:S64-S69.

  26. Chanyavanich V, Das SK, Lee WR, Lo JY. Knowledge based IMRT treatment planning for prostate cancer. Med Phys. 2011;38:2515–22.

    Article  PubMed  Google Scholar 

  27. Good D, Lo J, Lee WR, Wu QJ, Yin FF, Das SK. A knowledge-based approach to improving and homogenizing intensity modulated radiation therapy planning quality among treatment centers: an example application to prostate cancer planning. Int J Radiat Oncol Biol Phys. 2013;87:176–81.

    Article  PubMed  Google Scholar 

  28. Fogliata A, Wang PM, Belosi F, Clivio A, Nicolini G, Vanetti E, et al. Assessment of a model based optimization engine for volumetric modulated arc therapy for patients with advanced hepatocellular cancer. Radiat Oncol. 2014;9:236.

    Article  PubMed  PubMed Central  Google Scholar 

  29. Fogliata A, Belosi F, Clivio A, Navarria P, Nicolini G, Scorsetti M, et al. On the pre-clinical validation of a commercial model-based optimisation engine: application to volumetric modulated arc therapy for patients with lung or prostate cancer. Radiother Oncol. 2014;113:385–91.

    Article  PubMed  Google Scholar 

  30. Schmidt M, Lo JY, Grzetic S, Lutzky C, Brizel DM, Das SK. Semiautomated head-and-neck IMRT planning using dose warping and scaling to robustly adapt plans in a knowledge database containing potentially suboptimal plans. Med Phys. 2015;42:4428–34.

    Article  PubMed  Google Scholar 

  31. Fogliata A, Nicolini G, Clivio A, Vanetti E, Laksar S, Tozzi A. A broad scope knowledge based model for optimization of VMAT in esophageal cancer: validation and assessment of plan quality among different treatment centers. Radiat Oncol. 2015;10:220.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  32. Chang ATY, Hung AWM, Cheung FWK, Lee MCH, Chan OSH, Philips H, et al. Comparison of planning quality and efficiency between conventional and knowledge-based algorithms in nasopharyngeal Cancer patients using intensity modulated radiation therapy. Int J Radiat Oncol Biol Phys. 2016;95:981–90.

    Article  PubMed  Google Scholar 

  33. Fogliata A, Reggiori G, Stravato A, Lobefalo F, Franzese C, Franceschini D, et al. RapidPlan head and neck model: the objectives and possible clinical benefit. Radiat Oncol. 2017;12:73.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  34. Powis R, Bird A, Brennan M, Hinks S, Newman H, Reed K, et al. Clinical implementation of a knowledge based planning tool for prostate VMAT. Radiat Oncol. 2017;12:81.

    Article  PubMed  PubMed Central  Google Scholar 

  35. Wang J, Hu W, Yang Z, Chen X, Wu Z, Yu X, et al. Is it possible for knowledge-based planning to improve intensity modulated radiation therapy plan quality for planners with different planning experiences in left-sided breast cancer patients? Radiat Oncol. 2017;12:85.

    Article  PubMed  PubMed Central  Google Scholar 

  36. Ueda Y, Fukunaga JI, Kamima T, Adachi Y, Nakamatsu K, Monzen H. Evaluation of multiple institutions' models for knowledge-based planning of volumetric modulated arc therapy (VMAT) for prostate cancer. Radiat Oncol. 2018;13:46.

    Article  PubMed  PubMed Central  Google Scholar 

  37. Wall PDH, Carver RL, Fontenot JD. An improved distance-to-dose correlation for predicting bladder and rectum dose-volumes in knowledge-based VMAT planning for prostate cancer. Phys Med Biol. 2018;63:015035.

    Article  PubMed  Google Scholar 

  38. Voet PW, Dirkx ML, Breedveld S, Fransen D, Levendag PC, Heijmen BJ. Toward fully automated multicriterial plan generation: a prospective clinical study. Int J Radiat Oncol Biol Phys. 2013;85:866–72.

    Article  PubMed  Google Scholar 

  39. Kierkels RG, Korevaar EW, Steenbakkers RJ, Janssen T, van't Veld AA, Langendijk JA, et al. Direct use of multivariable normal tissue complication probability models in treatment plan optimisation for individualised head and neck cancer radiotherapy produces clinically acceptable treatment plans. Radiother Oncol. 2014;112:430–6.

    Article  PubMed  Google Scholar 

Download references

Availability of data and materials

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Author information

Authors and Affiliations

Authors

Contributions

JW, ZC and WL planned for treatment cases, performed the analysis and drafted the manuscript. WL, WQ and XW contributed to the data analysis and provided support with study design. JW and WH designed the study. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Weigang Hu.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wang, J., Chen, Z., Li, W. et al. A new strategy for volumetric-modulated arc therapy planning using AutoPlanning based multicriteria optimization for nasopharyngeal carcinoma. Radiat Oncol 13, 94 (2018). https://doi.org/10.1186/s13014-018-1042-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13014-018-1042-x

Keywords