Reply to Ghaffari et al. “In regard to Cuccia et al.: impact of hydrogel peri-rectal spacer insertion on prostate gland intra-fraction motion during 1.5 T MR-guided stereotactic body radiotherapy.”
Radiation Oncology volume 15, Article number: 213 (2020)
We kindly thank the letter by Ghaffari et al. [1] for their interesting observations concerning our recent study about the potential impact of hydrogel spacer on prostate intrafraction motion during 1.5 T MR-guided stereotactic body radiotherapy [2].
As we have already highlighted in the Discussion of our study, we agree with the Authors about the favorable effect of hydrogel spacer in terms of rectal wall sparing, while the potential impact in terms of organ motion still remains a matter of debate with currently available conflicting evidence [3,4,5].
As hypothesized by the Authors, a potential role of hydrogel spacer in limiting prostate motion may be related to the squeezing effect on the gland towards the pubic bone, which may also reflect on the theoretical impact on antero-posterior shifts. Conversely, the potential inflammatory reaction provided by the insertion of the gel was not observed in our cohort of patients, who well tolerated the procedure with no relevant aftermaths.
Nonetheless, our analysis confirmed a dosimetric advantage provided by the use of hydrogel spacer in terms of rectal dose exposure, also detecting a positive impact on rotational antero-posterior prostate shifts. Notably, in both the cohorts of patients, the comparison between the pre- and post-MRI sequences, that were considered as surrogates of any potential prostate displacement during the beam-on time, revealed median shift values within the PTV margins, with only a statistically significant difference in the A-P rotational direction. As this experience refers to the first 20 patients treated with MR-guided SBRT, no tolerance value was first set at the beginning of the study, but, with the exception of the A-P rotational shift, the magnitudes of displacement in all the other directions were comparable between the spacer and no-spacer subgroups.
However, a further cineMRI-based analysis of real-time organ motion in a larger sample cohort is currently ongoing in our Department, also with the aim to assess organs at risk motion during the beam-on phase.
Still, we reiterate that these preliminary data, despite being encouraging, need further support provided by long-term follow-up results both in terms of toxicity and larger samples of sessions. Whether the dosimetric advantage and the mitigation of prostate motion leads to a significant clinical benefit needs to be clarified. Consequently, although MR-guided radiotherapy has the potential to deeply refine the target volume delineation process and increase accuracy during the delivery phase [6], a margin reduction strategy would be currently unwise as organ motion uncertainty might be affected by several concurrent factors, as also recommended by other Authors [7].
Availability of data and materials
Not applicable.
Abbreviations
- MRI:
-
Magnetic resonance imaging
- PTV:
-
Planning target volume
- SBRT:
-
Stereotactic body radiotherapy
References
Ghaffari H, Navaser M, Refahi S. In regard to Cuccia et al.: impact of hydrogel peri-rectal spacer insertion on prostate gland intra-fraction motion during 1.5 T MR-guided stereotactic body radiotherapy. Radiat Oncol. 2020;15(1):199. https://doi.org/10.1186/s13014-020-01642-z.
Cuccia F, Mazzola R, Nicosia L, Figlia V, Giaj-Levra N, Ricchetti F, Rigo M, Vitale C, Mantoan B, De Simone A, Sicignano G, Ruggieri R, Cavalleri S, Alongi F. Impact of hydrogel peri-rectal spacer insertion on prostate gland intra-fraction motion during 1.5 T MR-guided stereotactic body radiotherapy. Radiat Oncol. 2020;15(1):178. https://doi.org/10.1186/s13014-020-01622-3.
Pinkawa M, Piroth MD, Holy R, Escobar-Corral N, Caffaro M, Djukic V, Klotz J, Eble MJ. Spacer stability and prostate position variability during radiotherapy for prostate cancer applying a hydrogel to protect the rectal wall. Radiother Oncol. 2013;106(2):220–4. https://doi.org/10.1016/j.radonc.2012.11.010.
Pinkawa M. Current role of spacers for prostate cancer radiotherapy. World J Clin Oncol. 2015;6(6):189–93. https://doi.org/10.5306/wjco.v6.i6.189.
Afkhami Ardekani M, Ghaffari H, Navaser M, et al. Effectiveness of rectal displacement devices in managing prostate motion: a systematic review. Strahlenther Onkol. 2020. https://doi.org/10.1007/s00066-020-01633-9.
Alongi F, Rigo M, Figlia V, Cuccia F, Giaj-Levra N, Nicosia L, Ricchetti F, Sicignano G, De Simone A, Naccarato S, Ruggieri R, Mazzola R. 1.5 T MR-guided and daily adapted SBRT for prostate cancer: feasibility, preliminary clinical tolerability, quality of life and patient-reported outcomes during treatment. Radiat Oncol. 2020;15(1):69. https://doi.org/10.1186/s13014-020-01510-w.
O'Neill AG, Jain S, Hounsell AR, O'Sullivan JM. Fiducial marker guided prostate radiotherapy: a review. Br J Radiol. 2016;89(1068):20160296. https://doi.org/10.1259/bjr.20160296.
Acknowledgements
None.
Funding
None.
Author information
Authors and Affiliations
Contributions
FC and FA equally contributed to the manuscript drafting. The author(s) read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
Filippo Alongi is a consultant and speaker honoraria for Elekta and Boston Scientific.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Cuccia, F., Alongi, F. Reply to Ghaffari et al. “In regard to Cuccia et al.: impact of hydrogel peri-rectal spacer insertion on prostate gland intra-fraction motion during 1.5 T MR-guided stereotactic body radiotherapy.”. Radiat Oncol 15, 213 (2020). https://doi.org/10.1186/s13014-020-01659-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s13014-020-01659-4