Skip to main content

The dosimetric impact of replacing the TG-43 algorithm by model based dose calculation for liver brachytherapy

Abstract

Purpose

To compare treatment plans for interstitial high dose rate (HDR) liver brachytherapy with 192Ir calculated according to current-standard TG-43U1 protocol with model-based dose calculation following TG-186 protocol.

Methods

We retrospectively evaluated dose volume histogram (DVH) parameters for liver, organs at risk (OARs) and clinical target volumes (CTVs) of 20 patient cases diagnosed with hepatocellular carcinoma (HCC) or metastatic colorectal cancer (mCRC). Dose calculations on a homogeneous water geometry (TG-43U1 surrogate) and on a computed tomography (CT) based geometry (TG-186) were performed using Monte Carlo (MC) simulations. The CTs were segmented based on a combination of assigning TG-186 recommended tissues to fixed Hounsfield Unit (HU) ranges and using organ contours delineated by physicians. For the liver, V5Gy and V10Gy were analysed, and for OARs the dose to 1 cubic centimeter (D1cc). Target coverage was assessed by calculating V150, V100, V95 and V90 as well as D95 and D90. For every DVH parameter, median, minimum and maximum values of the deviations of TG-186 from TG-43U1 were analysed.

Results

TG-186-calculated dose was found to be on average lower than dose calculated with TG-43U1. The deviation of highest magnitude for liver parameters was -6.2% of the total liver volume. For OARs, the deviations were all smaller than or equal to -0.5 Gy. Target coverage deviations were as high as -1.5% of the total CTV volume and -3.5% of the prescribed dose.

Conclusions

In this study we found that TG-43U1 overestimates dose to liver tissue compared to TG-186. This finding may be of clinical importance for cases where dose to the whole liver is the limiting factor.

Background

Since the publication of the report of the American Association of Physicists in Medicine’s (AAPM) Task Group (TG) 186 [1], which advocates the use of model-based dose calculation (MBDC) as replacement to the water kernel superposition algorithm recommended by the AAPM’s TG-43U1 [2], there has been a concerted effort to identify brachytherapy treatment sites necessitating more sophisticated dose calculations. Treatment sites analysed so far include prostate [3], breast [47], head and neck [8], esophagus [6] and gynecologic regions [6, 9, 10]. To our knowledge there are no studies on the effect of MBDC for liver brachytherapy. MBDC make use of tissue composition and mass density as estimated from x-ray computed tomography (CT) images of the patient to account for differential attenuation, scattering and absorption between tissues. An important application of MBDC is also applicator modelling [1]. Algorithms for MBDC of current interest for 192Ir brachytherapy include collapsed-cone point kernel superposition [1113], grid-based Boltzmann solvers [14, 15] as well as reference Monte Carlo (MC) simulation [16]. Different treatment planning systems (TPS) have adopted some of the algorithms listed above [13, 17]. In the context of 192Ir high dose rate (HDR) brachytherapy, the use of MBDC is particularly important for treatment sites in the vicinity of tissue/air or tissue/lung interfaces, and wherever variations of tissue density play an important role [1].

The treatment of liver malignancies by CT-guided HDR brachytherapy, where fluoroscopy-CT is employed for catheter insertion and three dimensional (3D) breath-hold CT for treatment planning, is associated with encouraging clinical results for liver metastases as well as hepatocellular carcinoma [18, 19]. It serves as an alternative to traditional treatment methodologies such as stereotactic body radiation therapy (SBRT) [2024], transarterial chemoembolization (TACE) [25, 26] and radiofrequency ablation (RFA) [27] for nonresectable tumours. At the hospital of the Ludwig-Maximilians-Universität München (LMU Munich), 196 patients were treated with interstitial brachytherapy for liver malignancies in 2018, and coincidentally also in 2019.

The goal of this study was to assess whether MBDC are required for accurate dosimetry of liver brachytherapy given the organ’s proximity to the lung, its higher density than water, and the proximity of organs at risks (OARs) such as the stomach or duodenum (in addition to healthy liver tissue). MBDC were retrospectively compared to TG-43U1 calculations for liver cancer cases treated with 192Ir HDR brachytherapy, by employing CT-based, gold-standard MC simulations performed with the AMIGOBrachy [28] platform. Dose volume histogram (DVH) indices for the clinical target volume (CTV), for the OARs and for the whole liver were compared between TG-186 and TG-43U1 dose distributions.

Materials and methods

Clinical cases

This study retrospectively evaluated 20 treatment plans of 18 patients (15 males and 3 females) who were diagnosed with either metastasized colorectal cancer (mCRC) or hepatocellular carcinoma (HCC) and were treated with interstitial CT-guided brachytherapy at the university hospital of the LMU Munich. The patients had one (10 cases) or multiple (10 cases) lesions in the liver. The total number of treated lesions was 41. CTVs showed a high variation in volume, from less than 1 cm3 up to about 280 cm3, and as a consequence the number of dwell positions per CTV ranged from less than 10 to 100. Doses of 12, 15, 20 or 25 Gy were prescribed and administered in a single fraction. The cases were selected to ensure a high variety and even distribution of prescription doses, number of CTVs, OAR types and medical diagnosis. Furthermore, no unused catheters were present and at least one OAR was delineated for every case. Table 1 contains more detailed information about the patients’ characteristics.

Table 1 Clinical situation of the 18 patients analysed in this study

Prior to treatment, brachytherapy catheters were inserted under fluoroscopy-CT guidance and local anaesthesia using a Seldinger technique. To achieve accurate placement of a catheter, a hollow gauge needle was first placed inside the lesion, then a stiff angiography guide wire was inserted into the needle. An angiography sheath was then inserted over the guide wire and the brachytherapy catheter was thereafter inserted into the angiography sheath [18, 29].

After successful placement of the catheters, a contrast-enhanced planning CT (SOMATOM Definition Edge, Siemens) was acquired using an end-of-exhale breathhold technique. Catheter reconstruction, treatment planning and dose optimization were performed with the Oncentra Brachy treatment planning system (Elekta AB, Stockholm, Sweden) which uses the dose calculation algorithm of the TG-43U1 protocol. For each case the CTVs were delineated, which correspond to the GTVs extended by a 0-1 mm margin. As there are few setup or motion uncertainties in brachytherapy, the planning target volume (PTV) is equal to the CTV. Furthermore, the whole liver and a set of OARs were contoured for clinical treatment planning, from which the most relevant were selected for analysis in this study. The stomach was the most frequent OAR (14 cases), followed by heart (8 cases), bowel and colon (7 cases), right kidney and duodenum (5 cases), esophagus (4 cases), bile duct (3 cases), and gall bladder (1 case). Table 1 lists the relevant OARs for each case.

Brachytherapy treatment was administered with an HDR afterloading system (Flexitron, Elekta AB, Stockholm, Sweden) using an 192Ir HDR source.

MC simulations

MC simulations were performed with MCNP6 (Monte Carlo n-Particle, version 1.0 [30]), which is integrated in the auxiliary software AMIGOBrachy [28]. A phase space source was used for calculation, validated in a previous study [31]. As a TG43-U1 surrogate, we employed an MC simulation with the whole patient geometry set to water (Dw,w). We used this instead of the TG-43U1 dose from the clinical TPS to avoid introducing biases which could be caused by TPS-specific aspects such as TG43-U1 parameter interpolation or cable modelling. For assessing dose transported in medium and scored in water (Dw,m) or scored in the medium itself (Dm,m), MC simulations were performed on a heterogeneous patient model (TG-186) based on the CT geometry. The CT images were segmented using auxiliary software, AMIGOBrachy [28], to create voxel geometries consisting of 5 tissues (lung (ρ = 0.26 g/cm3), mean adipose tissue (ρ = 0.95 g/cm3), mean male soft tissue (ρ = 1.03 g/cm3), mean female soft tissue (ρ = 1.02 g/cm3), liver (ρ = 1.06 g/cm3), and cortical bone (ρ = 1.92 g/cm3)), with compositions and densities recommended by TG-186 [1], and air (ρ = 0.0012 g/cm3).

The segmentation was performed by assigning homogeneous densities corresponding to the tissues specified above to fixed Hounsfield Unit (HU) ranges (see Table 2). We chose to assign reference densities instead of densities derived from a CT calibration curve to account for variations in density in organs which contained contrast agent, since during the time period from CT acquisition to treatment administration the contrast agent concentration decreased in the patient. In every case the liver was overwritten with a homogeneous density and composition according to TG-186, using the delineated organ contours. Parts of certain OARs (heart, kidney) were initially misassigned due to a high concentration of contrast agent. In these cases, the affected voxels were overwritten with mean male/female soft tissue density and composition.

MC calculations were performed on an interpolated version of the CT grid. Voxel dimensions within transversal planes of the CT grid ranged from 0.61 mm to 0.98 mm for the different cases and were deemed small enough for direct adoption to the dose calculation grid of the simulation. CT slice resolution ranged from 2 mm to 3 mm and was interpolated to enable a dose grid slice resolution of 1 mm. Dose values were approximated as collision kerma assuming charged particle equilibrium, so secondary electrons were not transported [32, 33]. Simulations were performed using a track length tally and adopting mass-energy absorption coefficients (μen/ρ) from the National Institute of Standards and Technology (NIST) [34] for either water (Dw,m) or medium (Dm,m) to convert photon energy fluence to collision kerma/dose. Calculations were performed using the 192Ir photon spectrum available from the National Nuclear Data Center [35]. The calculation method has been described in detail by Fonseca et al [28,31] and was also used by several authors [3638]. The dose was cut off at a maximum value of 200 Gy for better comparison with the TPS, which uses this cutoff as a standard. MC uncertainties for all cases were assessed by calculating the voxel-wise standard deviation of repeated MC simulations and determining its maximum value within the 30%-isodose line (relative to prescription dose) for Dw,w and Dw,m. Dm,m uncertainties are of the same magnitude as Dw,m uncertainties for the calculation method used in this study. We set the number of particles (up to 4x1010 for the different cases) such that Dw,w standard deviations within the 30%-isodose line were all below 0.8% and Dw,m standard deviations below 1.3%. To analyse the influence of these uncertainties on DVH parameter estimation we repeated the simulation for case iv (chosen arbitrarily) after increasing the number of histories by a factor of 10 and compared the DVH parameters with the results for the original number of histories. This led to deviations in the DVH-parameters that were all smaller than 0.2% of the respective DVH parameter value and were therefore considered negligible.

Table 2 Hounsfield Unit thresholds used for tissue segmentation

Dosimetric comparison

To evaluate differences between TG-43U1 and TG-186 in terms of clinically relevant quantities, DVH parameters were calculated for the liver, OARs and CTVs. To assess liver toxicity, the fractional liver volumes receiving at least 5 Gy or 10 Gy were calculated (V5Gy and V10Gy, respectively). For each OAR, the dose to 1 cubic centimeter (D1cc) was calculated. For the CTVs we considered the fractional volumes receiving at least 150%, 100%, 95% or 90% of the prescribed dose (V150, V100, V95 and V90, respectively), and the doses that were administered to 95% or 90% of the CTV volumes (D95 and D90, respectively).

We determined for each DVH parameter the median, minimum and maximum values over all treatment plans, calculated with Dw,w. To analyse the deviations between TG43-U1 and TG-186 we considered the absolute difference of TG-186-calculated parameters from Dw,w. Median, minimum and maximum of these deviations were calculated. For liver and OARs, the DVH parameters were compared to clinical tolerance limits.

Results

We report the comparison of Dw,w and Dw,m in the following subsections, divided into liver, OAR and CTV DVH parameter analysis. All of the reported results were obtained by MC simulations. Tables with the values for Dm,m were not included, since the results were similar to the comparison of Dw,m and Dw,w and thus do not provide additional insights. For completeness they can be found in the Appendix (Tables 6, 7 and 8).

For an easier comparison between parameters, we also included the deviations from TG-43U1 in percentage of the corresponding parameter value. The tables can be found in the Supplementary material (S1, S2 and S3).

Liver dose

As an assessment of the influence of TG-186 on DVH parameters for the liver, we report Dw,w-calculated parameters as well as the absolute difference between Dw,m- and Dw,w-calculated parameters for V5Gy and V10Gy shown in Table 3 and Fig. 1a. The median of Dw,w was well within clinical tolerance levels, the maximum values exceeded tolerances by a few percent for both V5Gy and V10Gy. The values of V5Gy and V10Gy showed a very high spread, ranging from a few percent to values above the tolerance limit. The deviations were most pronounced for V5Gy, ranging from -0.05% to -6.2%. V10Gy-deviations ranged from -0.01% to -1.7%. The median deviation was -0.8% for V5Gy and -0.2% for V10Gy.

Fig. 1
figure 1

Deviations of DVH parameters calculated with Dw,m from Dw,w for liver and OARs. IQR stands for interquartile range, which is equal to the spread of the central 50% of the data. a Deviations for liver parameters. b Deviations for selected OARs

Table 3 Comparison of Dw,w and Dw,m for liver DVH parameters

For the case with highest deviation (case ii, -6.2%) the V5Gy-parameter calculated with Dw,w was also the maximum value of all cases, 72%. It exceeded the tolerance of 67%. With the reduction of -6.2%, the Dw,m-calculated value was just below the tolerance limit (66%). The V10Gy-parameter was also quite high (26%), but did not exceed the tolerance of 33%. For this value, the deviation was -1.7%, which is also the deviation of highest magnitude over all cases for the V10Gy-parameter.

Figure 2 shows the dose distributions for this case and three other cases, calculated with Dw,w. For case i, the reduction of the V5Gy when comparing Dw,m to Dw,w is clearly visible in the region between two CTVs. The liver is only partly covered by the 5-Gy-isodose line. For case ii, the volume of the Dw,m-calculated 5-Gy-isodose is notably smaller than the Dw,w-calculated volume. Both cover a large part of the liver. This can also be seen in case iv, where Dw,w and Dw,m show a deviation close to the body surface. A large part of the liver is enclosed by the 5-Gy-isodose lines in this case. For case xix, the Dw,w- and Dw,m-isodose lines are quite close together, except at lung-tissue interface regions.

Fig. 2
figure 2

Dose distributions of Dw,w for coronal slices of 4 different cases. The dose profile is normalised so that 100% dose equals 5 Gy. Overlaid are the contours of the 5-Gy-isodose lines of Dw,w (light blue) and Dw,m (yellow). Additional contours show the liver (dark red) and one or more CTVs (red). This figure focuses on the analysis of the V5Gy-parameter and is not suitable for evaluation of target coverage, since the CTVs are not always shown. a case i. b case ii. c case iv. d case xix

OAR dose

For the OARs we report the difference between Dw,m and Dw,w for D1cc of each OAR type (see Table 4 and Fig. 1b). The differences in D1cc ranged from -0.02 Gy to -0.5 Gy. The median differences were of similar magnitude for all types of OAR. The highest deviations were found for colon (-0.5 Gy, -4.8% relative to Dw,w-value) and stomach (-0.5 Gy, -3.7% relative to Dw,w-value) of case iv.

Table 4 Comparison of Dw,w and Dw,m for D1cc of the selected OARs

The median Dw,w-values were within clinical tolerance limits for most OAR types. There was one case where the D1cc of the stomach exceeded the limit of 12 Gy both when calculated with Dw,w (14.2 Gy) and Dw,m (13.7 Gy).

Target coverage

Table 5 shows the values of the CTV DVH parameters, calculated for Dw,w, as well as deviations of Dw,m-calculated values from the latter. The deviations are also visualized in Fig. 3a and b. We observed little change for V100, V95 and V90 when comparing Dw,m and Dw,w, with the median deviation being -0.05% for V100, -0.02% for V95 and -0.01% for V90. The most important deviation of these parameters was -0.8%. Figure 3a shows that most of the values are concentrated in a range of very low deviation with only a few exceptions. V150 showed a higher deviation of Dw,m from Dw,w with a median of -0.4% and a maximum deviation in absolute terms of -1.5%. V150-deviations were more widely spread.

Fig. 3
figure 3

Deviations of DVH parameters used to analyse target coverage. IQR stands for interquartile range, which is equal to the spread of the central 50% of the data. a Deviations of CTV volume parameters. b Deviations of CTV dose parameters

Table 5 Comparison of Dw,w and Dw,m for CTV DVH parameters

Concerning the dose parameters D95 and D90, the deviations from TG-43U1 had a median value of -0.9% of the prescribed dose for D95 and D90. The deviations of largest magnitude were -3.5% for D95 and -3.4% of the prescribed dose for D90. For D95, the maximum deviation was found to be 0.3% of the prescribed dose. Since this value corresponds to 0.07 Gy in absolute units, it is considered negligible. The maximum values of D95 (256% of the prescribed dose) and D90 (302% of the prescribed dose) corresponded to a case where two CTVs were located very close to one another which resulted in an accumulation of dose in that region.

Discussion

Our calculations found TG-186-calculated DVH-parameters to be in general lower than TG-43U1-calculated parameters. This is in good agreement with the results of other groups who reported an overestimation of TG-43U1 in comparison to TG-186 for soft tissue in other tumour entities [4,6,8,10]. For breast cancer cases, Thrower et al. compared TG-43 to Dm,m and reported relative percentage changes of 1.2% for V100, 0.86% for V95 and 0.47% for V90. Deviations in D1cc were 3.1% for the rib, 2.5% for the skin and 3.1% for the lung [4]. Fotina et al. found a relative percentage change in target coverage of about 2% for breast, esophageal and gynecologic cases, comparing Dw,m to TG-43 [6]. Peppa et al. reported changes when comparing Dm,m to TG-43 of up to 2% relative to the prescription dose for head and neck cancer. Regarding target coverage, relative deviations were as high as 9.1% for V200 and 5.2% for V150 [8]. For cervix cancer patients, Jacob et al. compared TG-43 to Dm,m and reported changes in target coverage parameter D90 of 2.6%, with similar values for D95 and D100. They found an average relative change of 2.8% in D1cc for rectum, bladder and sigmoid [10].

We decided to focus on Dw,m-values in the comparison to Dw,w, since Dm,m-values were very similar to Dw,m. This was expected for soft tissues in the range of 192Ir-energies [1] and will therefore not be further addressed in this study.

Liver dose

The deviations of the V5Gy- and V10Gy-parameter are of a magnitude that may be clinically relevant, especially V5Gy shows large differences between Dw,w and Dw,m. Since deviations differed strongly from case to case, we tried to find a case-specific feature determining the magnitude of deviation. As a first attempt, we looked at the dependence of deviations on the V5Gy-parameter. This volume was usually very large compared to other volume parameters (V95, V90) resulting in a large travel distance for photons through the liver. Since liver density is higher than water density, photons do not travel as far as in water, and the Dw,m-isodose line is pulled back in comparison to Dw,w. This effect should be more pronounced for higher values of the V5Gy-parameter due to an increase in photon travel distance.

To find correlations of the deviations of V5Gy and the V5Gy-parameter itself, we plotted in Fig. 4 the relative deviations \(\frac {V_{\mathrm {5Gy;w,m}} - V_{\mathrm {5Gy;w,w}}}{V_{\mathrm {5Gy;w,w}}}\) over V5Gy;w,w in cm3. Since absolute deviations are expected to scale with V5Gy;w,w, relative deviations are shown in this plot. Furthermore, since total liver volumes can vary a lot among patients, we show the V5Gy-parameter in absolute units of cm3 instead of percentages.

Fig. 4
figure 4

Relative deviations of the V5Gy-parameter from TG-43U1, plotted over the respective TG-43U1 parameter value in cm3. The labels correspond to the cases shown in Fig. 2

Due to a number of factors such as the large spread of prescription doses, the variation in number and size of CTVs and the location of CTVs, there is also a large spread in the values of the V5Gy-parameter. The plot shows that cases with a larger V5Gy;w,w tend to have relative deviations of larger magnitude. This tendency also explains why deviations of the V10Gy-parameter, which is usually much smaller than the V5Gy-parameter, are also smaller in general. Cases marked in the plot correspond to those shown in Fig. 2. The effect of a higher V5Gy-volume on the separation of the two isodose lines is clearly visible when comparing case i (Fig. 2a) to the other cases (Fig. 2b-d), neglecting for case i the region between the two CTVs where the separation of the isodose lines is larger.

Other groups also suggested a correlation between deviations from TG-43U1 and photon travel distance path. Thrower et al. and Zourari et al. found that deviations increased with increasing distance from dwell positions [4,5] for breast cases, although in that case this was mostly due to lung heterogeneities.

Apart from a pure dependency on photon travel distance we also found other possible influences of the magnitude of the V5Gy-parameter deviation. An example is case i: if we look at Fig. 2a, we see that this case had multiple treated CTVs (3 in total) and the dose in the overlap region between two CTVs was very close to 5 Gy. Since this region is fully enclosed by the liver, it has a high influence on the V5Gy-parameter deviation. This example shows that the number of source positions or CTVs per case may play a role in the magnitude of deviations of the V5Gy-parameter, given that the dose between CTVs is in the range of 5 Gy and the CTVs are not too close together.

Another influence on the V5Gy-parameter is shown in case iv (Fig. 2c). We can see that the V5Gy-volume is very large and only a smaller part of the liver is actually influenced by the deviations of Dw,w and Dw,m. This example demonstrates that not only the magnitude of the V5Gy-parameter has an influence on the magnitude of the deviation from TG-43U1, but that also the location of the 5-Gy-isodose lines and therefore of the CTVs is important. If the isodose lines are located mostly inside of the liver, deviations will be much more pronounced than in cases like case iv, where most of the isodose lines are outside of the liver.

As can be seen in cases ii, iv and xix (Fig. 2b, c, d), proximity to lung, body surface or bone also has an influence on the 5-Gy-isodose. However, since sources are always placed inside the liver and only the percentage of the V5Gy-volume that covers the liver is clinically relevant, these factors do not have a strong influence on the parameter itself. Only in cases where the 5-Gy-isodose line lies within the liver and at the same time close to a lung-tissue interface region (see Fig. 2d), loss of backscatter due to less photon attenuation in low-density tissue and therefore a reduction in Dw,m-dose is visible.

The data analysed in this study suggests that replacing TG-43U1 with TG-186 may be of clinical relevance if we look at typical parameters for the assessment of liver toxicity. There were a few cases where liver parameters were close to the tolerance limit. TG-186-calculated parameters showed a reduction in these parameters of up to 6.2% of the absolute liver volume. This result is important in clinical decision making regarding cases where a sufficient local tumour control can only be achieved by giving a relatively high dose to a large part of the liver. The wide spread of relative deviations for the V5Gy-parameter from a few percent up to almost -9% (see Fig. 4) shows that there is a variety between cases that is not taken into account when only TG-43U1 is used for dose calculations. Studies have been performed on the tolerance of liver tissue to brachytherapy using radiation-induced liver damage (RILD) as a biological endpoint [39]. Our findings support a reassessment of current tolerance limits when computing dose following TG-186.

OAR dose

For the OARs, the deviations in absolute terms were small. There was one case (case iv) where the difference was -0.5 Gy for colon and for stomach. These organs were analysed in the CT images and a possible reason for increased deviations could be a larger distance from the brachytherapy source and therefore a reduction in dose because photons are travelling through liver tissue of higher density. However, this reduction is too small to have an impact on clinical treatment planning dose.

Target coverage

CTV volume parameters V100, V95 and V90 show very small deviations from Dw,w for most of the cases. This is primarily due to a very good coverage of the CTVs: For V100, V95 and V90 the median value of Dw,w was 100%. Therefore, any deviations from TG-43U1 can hardly be seen in these parameters. V150 has a median value of 85% and shows higher deviations from TG-43U1. This can be explained by the fact that this parameter was always located in a region of higher gradient of the DVH, where small deviations cause a major change of parameter value. These results agree with the findings of other groups who also reported an increase in deviations for V150 compared to the other volume parameters [5,8]. However, V150 and V100 are of little clinical relevance in brachytherapy for liver metastases, because there is no demand for a homogeneous dose profile in the target volumes. These parameters were mainly included for better comparison to other brachytherapy treatment sites such as breast, where they play an important role in determining plan quality.

The dose parameters D95 and D90 show slightly larger deviations than the volume parameters when comparing the percentage values. This can be explained by the fact that these values are located in the gradient of the DVH curve, and no longer in the plateau like most of the volume parameters. Still, these deviations are all well below 1 Gy and will therefore have no major influence on the target coverage.

In this study we observed that the location and number of dwell positions as well as the liver volume are important parameters that influence the magnitude of deviations between TG-43U1 and TG-186, thus it may be interesting to systematically investigate their combined effect. For cases where doses to the whole liver are close to tolerance limits and where TG-186 dose is notably reduced compared to dose calculated by TG-43U1, a reassessment of tolerance doses may be beneficial. Further studies are needed to investigate this issue, since model-based dose calculations are not yet used as a standard in clinical practice.

The results of this study are limited by the tissue segmentation which only included 5 tissues. Furthermore, there was a high variety in number, size and location of CTVs, number and type of OARs and prescription doses, which makes a quantitative comparison between cases difficult.

Photon propagation through medium leads to modifications in the energy spectrum which increase with larger distance from the source. For 192Ir, modifications were found to be of a relevant magnitude in a previous study [31]. This can lead to errors in the conversion of Dw,m to Dm,m and vice versa. Since both of these properties were calculated on the fly in MCNP instead of employing any conversion factors, our results are not affected by these errors.

Since the liver is subject to a lot of intrafractional motion and treatment times can take up to 60 min [40], performing dose calculations on 4DCT data would be highly useful for estimating additional dose calculation errors due to motion. Respiratory motion has proven to have an impact on stereotactic ablative radiotherapy (SABR) plans for the treatment of hepatocellular carcinoma [41] due to the high magnitude of liver motion, which can exceed 5 mm even during usage of abdominal compression [42] and is different for different liver segments [43]. Another area of interest would be cases where the lung or parts of the bone, e.g. the thoracic wall, are considered to be OARs. Due to the highly different density compared to water these organs would supposedly be more sensitive to deviations of TG-186 from TG-43U1.

Conclusion

This study is to our knowledge the first one comparing TG-43U1 to TG-186 for the interstitial 192Ir HDR brachytherapy treatment of liver metastases and hepatocellular carcinoma. We found a general overestimation of DVH parameters by TG-43U1 compared to TG-186, especially regarding the liver V5Gy-parameter, of up to 6.2% of liver volume. Deviations from TG-43U1 regarding dose to OARs and target coverage were all well below 1 Gy. We conclude that there may be a clinical benefit of reporting TG-186 alongside TG-43U1 for cases where differences between the calculation methods are high and doses to the whole liver are close to tolerance limits.

Appendix

Table 6 Comparison of Dw,w and Dw,m as well as Dw,w and Dm,m for liver DVH parameters
Table 7 Comparison of Dw,w and Dw,m as well as Dw,w and Dm,m for D1cc of the selected OARs
Table 8 Comparison of Dw,w and Dw,m as well as Dw,w and Dm,m for CTV DVH parameters

Availability of data and materials

The datasets supporting the conclusions of this article are included within the article.

Abbreviations

4DCT:

Four-dimensional computed tomography

AAPM:

American Association of Physicists in Medicine

CTV:

Clinical target volume

CT:

Computed tomography

D 1cc :

Dose received by 1 cubic centimeter

D 95 :

Dose received by 95% of the volume

D 90 :

Dose received by 90% of the volume

DVH:

Dose volume histogram

D m,m :

Dose calculated and scored in medium

D w,m :

Dose calculated in medium and scored in water

D w,w :

Dose calculated and scored in water

Gy:

Gray

HCC:

Hepatocellular carcinoma

HDR:

High dose rate

HU:

Hounsfield Unit

IQR:

Interquartile range

Ir:

Iridium

mCRC:

Metastatic colorectal cancer

MBDC:

Model-based dose calculation

MC:

Monte Carlo

MCNP:

Monte Carlo n-Particle

OAR:

Organ at risk

PTV:

Planning target volume

RFA:

Radiofrequency ablation

RILD:

Radiation-induced liver damage

SABR:

Stereotactic ablative radiotherapy

SBRT:

Stereotactic body radiation therapy

TACE:

Transarterial chemoembolization

TG:

Task group

TPS:

Treatment planning system

V 5Gy :

Volume receiving at least 5 Gy

V 10Gy :

Volume receiving at least 10 Gy

V 150 :

Volume receiving at least 150% of the prescribed dose

V 100 :

Volume receiving at least 100% of the prescribed dose

V 95 :

Volume receiving at least 95% of the prescribed dose

V 90 :

Volume receiving at least 90% of the prescribed dose

References

  1. Beaulieu L, Carlsson Tedgren Å, Carrier JF, Davis SD, Mourtada F, Rivard MJ, Thomson RM, Verhaegen F, Wareing TA, Williamson JF. Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: Current status and recommendations for clinical implementation. Med Phys. 2012; 39(10):6208–36. https://doi.org/10.1118/1.4747264.

    Article  PubMed  Google Scholar 

  2. Rivard MJ, Coursey BM, DeWerd LA, Hanson WF, Saiful Huq M, Ibbott GS, Mitch MG, Nath R, Williamson JF. Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. Med Phys. 2004; 31(3):633–74.

    Article  PubMed  Google Scholar 

  3. Afsharpour H, D’Amours M, Coté B, Carrier J-F, Verhaegen F, Beaulieu L. A Monte Carlo study on the effect of seed design on the interseed attenuation in permanent prostate implants. Med Phys. 2008; 35(8):3671–81. https://doi.org/10.1118/1.2955754.

    Article  PubMed  Google Scholar 

  4. Thrower SL, Shaitelman SF, Bloom E, Salehpour M, Gifford K. Comparison of Dose Distributions With TG-43 and Collapsed Cone Convolution Algorithms Applied to Accelerated Partial Breast Irradiation Patient Plans. Int J Radiat Oncol Biol Phys. 2016; 95(5):1520–6. https://doi.org/10.1016/j.ijrobp.2016.03.033.

    Article  PubMed  Google Scholar 

  5. Zourari K, Major T, Herein A, Peppa V, Polgár C, Papagiannis P. A retrospective dosimetric comparison of TG43 and a commercially available MBDCA for an APBI brachytherapy patient cohort. Phys Medica. 2015; 31(7):669–76. https://doi.org/10.1016/j.ejmp.2015.05.010.

    Article  CAS  Google Scholar 

  6. Fotina I, Zourari K, Lahanas V, Pantelis E, Papagiannis P. A comparative assessment of inhomogeneity and finite patient dimension effects in 60Co and 192Ir high-dose-rate brachytherapy. J Contemp Brachytherapy. 2018; 10(1):73–84. https://doi.org/10.5114/jcb.2018.74327.

    Article  PubMed  PubMed Central  Google Scholar 

  7. White SA, Landry G, van Gils F, Verhaegen F, Reniers B. Influence of trace elements in human tissue in low-energy photon brachytherapy dosimetry. Phys Med Biol. 2012; 57(11):3585–96. https://doi.org/10.1088/0031-9155/57/11/3585.

    Article  CAS  PubMed  Google Scholar 

  8. Peppa V, Pappas E, Major T, Takácsi-Nagy Z, Pantelis E, Papagiannis P. On the impact of improved dosimetric accuracy on head and neck high dose rate brachytherapy. Radiother Oncol. 2016; 120(1):92–97. https://doi.org/10.1016/j.radonc.2016.01.022.

    Article  PubMed  Google Scholar 

  9. Abe K, Kadoya N, Sato S, Hashimoto S, Nakajima Y, Miyasaka Y, Ito K, Umezawa R, Yamamoto T, Takahashi N, Takeda K, Jingu K. Impact of a commercially available model-based dose calculation algorithm on treatment planning of high-dose-rate brachytherapy in patients with cervical cancer. J Radiat Res. 2018; 59(2):198–206. https://doi.org/10.1093/jrr/rrx081.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  10. Jacob D, Lamberto M, DeSouza Lawrence L, Mourtada F. Clinical transition to model-based dose calculation algorithm: A retrospective analysis of high-dose-rate tandem and ring brachytherapy of the cervix. Brachytherapy. 2017; 16(3):624–9. https://doi.org/10.1016/j.brachy.2017.02.008.

    Article  PubMed  Google Scholar 

  11. Terribilini D, Vitzthum V, Volken W, Frei D, Loessl K, van Veelen B, Manser P, Fix MK. Performance evaluation of a collapsed cone dose calculation algorithm for HDR Ir-192 of APBI treatments. Med Phys. 2017; 44(10):5475–85. https://doi.org/10.1002/mp.12490.

    Article  CAS  PubMed  Google Scholar 

  12. Ahnesjö A. Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media. Med Phys. 1989; 16(4):577–92. https://doi.org/10.1118/1.596360.

    Article  PubMed  Google Scholar 

  13. Ma Y, Lacroix F, Lavallée M-C, Beaulieu L. Validation of the Oncentra Brachy Advanced Collapsed cone Engine for a commercial 192Ir source using heterogeneous geometries. Brachytherapy. 2015; 14. https://doi.org/10.1016/j.brachy.2015.08.003.

    Article  PubMed  Google Scholar 

  14. Hofbauer J, Kirisits C, Resch A, Xu Y, Sturdza A, Pötter R, Nesvacil N. Impact of heterogeneity-corrected dose calculation using a grid-based Boltzmann solver on breast and cervix cancer brachytherapy. J Contemp Brachytherapy. 2016; 8(2):143–9. https://doi.org/10.5114/jcb.2016.59352.

    Article  PubMed  PubMed Central  Google Scholar 

  15. Vassiliev O, Wareing T, McGhee J, Failla G, Salehpour M, Mourtada F. Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams. Phys Med Biol. 2010; 55(3):581–98. https://doi.org/10.1088/0031-9155/55/3/002.

    Article  PubMed  Google Scholar 

  16. Rogers DWO. Fifty years of Monte Carlo simulations for medical physics. Phys Med Biol. 2006; 51(13):287–301. https://doi.org/10.1088/0031-9155/51/13/r17.

    Article  Google Scholar 

  17. Krause F, Risske F, Bohn S, Delaperriere M, Dunst J, Siebert F-A. End-to-end test for computed tomography-based high-dose-rate brachytherapy. J Contemp Brachytherapy. 2018; 10(6):551–8. https://doi.org/10.5114/jcb.2018.81026.

    Article  PubMed  PubMed Central  Google Scholar 

  18. Ricke J, Wust P. Computed Tomography-Guided Brachytherapy for Liver Cancer. Semin Radiat Oncol. 2011; 21(4):287–93. https://doi.org/10.1016/j.semradonc.2011.05.005.

    Article  PubMed  Google Scholar 

  19. Kieszko D, Cisek P, Kordzińska-Cisek I, Grzybowska-Szatkowska L. Treatment of hepatic metastases with computed tomography-guided interstitial brachytherapy. Oncol Lett. 2018; 15(6):8717–22. https://doi.org/10.3892/ol.2018.8415.

    PubMed  PubMed Central  Google Scholar 

  20. Gerum S, Heinz C, Belka C, Walter F, Paprottka P, De Toni EN, Roeder F. Stereotactic body radiation therapy (SBRT) in patients with hepatocellular carcinoma and oligometastatic liver disease. Radiat Oncol. 2018; 13(1). https://doi.org/10.1186/s13014-018-1048-4.

  21. Hass P, Mohnike K, Kropf S, Brunner TB, Walke M, Albers D, Petersen C, Damm R, Walter F, Ricke J, Powerski M, Corradini S. Comparative analysis between interstitial brachytherapy and stereotactic body irradiation for local ablation in liver malignancies. Brachytherapy. 2019; 18(6):823–8. https://doi.org/10.1016/j.brachy.2019.08.003.

    Article  PubMed  Google Scholar 

  22. Scorsetti M, Comito T, Clerici E, Franzese C, Tozzi A, Iftode C, Di Brina L, Navarria P, Mancosu P, Reggiori G, Fogliata A, Tomatis S, Torzilli G, Cozzi L. Phase II trial on SBRT for unresectable liver metastases: long-term outcome and prognostic factors of survival after 5 years of follow-up. Radiat Oncol. 2018; 13(1):234. https://doi.org/10.1186/s13014-018-1185-9.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  23. Mahadevan A, Blanck O, Lanciano R, Peddada A, Sundararaman S, D’Ambrosio D, Sharma S, Perry D, Kolker J, Davis J. Stereotactic Body Radiotherapy (SBRT) for liver metastasis – clinical outcomes from the international multi-institutional RSSearch® Patient Registry. Radiat Oncol. 2018; 13(1):26. https://doi.org/10.1186/s13014-018-0969-2.

    Article  PubMed  PubMed Central  Google Scholar 

  24. Gkika E, Schultheiss M, Bettinger D, Maruschke L, Neeff HP, Schulenburg M, Adebahr S, Kirste S, Nestle U, Thimme R, Grosu A-L, Brunner TB. Excellent local control and tolerance profile after stereotactic body radiotherapy of advanced hepatocellular carcinoma. Radiat Oncol. 2017; 12(1):116.

    Article  PubMed  PubMed Central  Google Scholar 

  25. Mohnike K, Steffen IG, Seidensticker M, Hass P, Damm R, Peters N, Seidensticker R, Schütte K, Arend J, Bornschein J, Streitparth T, Wybranski C, Wieners G, Stübs P, Malfertheiner P, Pech M, Ricke J. Radioablation by Image-Guided (HDR) Brachytherapy and Transarterial Chemoembolization in Hepatocellular Carcinoma: A Randomized Phase II Trial. Cardiovasc Intervent Radiol. 2019; 42(2):239–49. https://doi.org/10.1007/s00270-018-2127-5.

    Article  PubMed  Google Scholar 

  26. Shiba S, Shibuya K, Katoh H, Kaminuma T, Miyazaki M, Kakizaki S, Shirabe K, Ohno T, Nakano T. A comparison of carbon ion radiotherapy and transarterial chemoembolization treatment outcomes for single hepatocellular carcinoma: a propensity score matching study. Radiat Oncol. 2019; 14(1):137. https://doi.org/10.1186/s13014-019-1347-4.

    Article  PubMed  PubMed Central  Google Scholar 

  27. Schnapauff D, Collettini F, Steffen I, Wieners G, Hamm B, Gebauer B, Maurer MH. Activity-based cost analysis of hepatic tumor ablation using CT-guided high-dose rate brachytherapy or CT-guided radiofrequency ablation in hepatocellular carcinoma. Radiat Oncol. 2016; 11(1):1–9. https://doi.org/10.1186/s13014-016-0606-x.

    Article  Google Scholar 

  28. Fonseca GP, Reniers B, Landry G, White S, Bellezzo M, Antunes PCG, de Sales CP, Welteman E, Yoriyaz H, Verhaegen F. A medical image-based graphical platform-Features, applications and relevance for brachytherapy. Brachytherapy. 2014; 13(6):632–9. https://doi.org/10.1016/j.brachy.2014.07.004.

    Article  PubMed  Google Scholar 

  29. Bretschneider T, Ricke J, Gebauer B, Streitparth F. Image-guided high-dose-rate brachytherapy of malignancies in various inner organs-technique, indications, and perspectives. J Contemp Brachytherapy. 2016; 8(3):251–61. https://doi.org/10.5114/jcb.2016.61068.

    Article  PubMed  Google Scholar 

  30. Goorley T, James M, Booth T, Brown F, Bull J, Cox LJ, Durkee J, Elson J, Fensin M, Forster RA, Hendricks J, Hughes HG, Johns R, Kiedrowski B, Martz R, Mashnik S, McKinney G, Pelowitz D, Prael R, Sweezy J, Waters L, Wilcox T, Zukaitis T. Initial MCNP6 release overview. Nucl Technol. 2012; 180(3):298–315. https://doi.org/10.13182/NT11-135.

    Article  CAS  Google Scholar 

  31. Fonseca GP, Tedgren Å. C., Reniers B, Nilsson J, Persson M, Yoriyaz H, Verhaegen F. Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium. Phys Med Biol. 2015; 60(11):4565–79. https://doi.org/10.1088/0031-9155/60/11/4565.

    Article  PubMed  Google Scholar 

  32. Ballester F, Granero D, Ṕrez-Calatayud J, Melhus CS, Rivard MJ. Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons. Med Phys. 2009; 36(9):4250–6. https://doi.org/10.1118/1.3194754.

    Article  CAS  PubMed  Google Scholar 

  33. Wang R, Li XA. Dose characterization in the near-source region for two high dose rate brachytherapy sources. Med Phys. 2002; 29(8):1678–86. https://doi.org/10.1118/1.1493780.

    Article  PubMed  Google Scholar 

  34. Berger MJ, Hubbell JH, Seltzer SM, Chang J, Coursey JS, Sukumar R, Zucker DS, Olsen K. XCOM: Photon Cross Section Database (Version 1.3). 2005. https://www.nist.gov/pml/xcom-photon-cross-sections-database.

  35. Baglin CM. Nuclear Data Sheets for A = 192. Nucl Data Sheets. 2012. https://doi.org/10.1016/j.nds.2012.08.001.

    Article  CAS  Google Scholar 

  36. Taylor REP, Rogers DWO. EGSnrc Monte Carlo calculated dosimetry parameters for 192Ir and 169Yb brachytherapy sources. Med Phys. 2008; 35(11):4933–44. https://doi.org/10.1118/1.2987676.

    Article  CAS  PubMed  Google Scholar 

  37. Ma Y, Vijande J, Ballester F, Tedgren Å. C., Granero D, Haworth A, Mourtada F, Fonseca GP, Zourari K, Papagiannis P, Rivard MJ, Siebert FA, Sloboda RS, Smith R, Chamberland MJP, Thomson RM, Verhaegen F, Beaulieu L. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192Ir brachytherapy:. Med Phys. 2017; 44(11):5961–76. https://doi.org/10.1002/mp.12459.

    Article  CAS  PubMed  Google Scholar 

  38. Ballester F, Carlsson Tedgren Å, Granero D, Haworth A, Mourtada F, Fonseca GP, Zourari K, Papagiannis P, Rivard MJ, Siebert FA, Sloboda RS, Smith RL, Thomson RM, Verhaegen F, Vijande J, Ma Y, Beaulieu L. A generic high-dose rate 192Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism. Med Phys. 2015; 42(6). https://doi.org/10.1118/1.4921020.

    Article  CAS  PubMed  Google Scholar 

  39. Seidensticker M, Burak M, Kalinski T, Garlipp B, Koelble K, Wust P, Antweiler K, Seidensticker R, Mohnicke K, Pech M, Ricke J. Radiation-Induced Liver Damage: Correlation of Histopathology with Hepatobiliary Magnetic Resonance Imaging, a Feasibility Study. Cardiovasc Intervent Radiol. 2015; 38:213–21. https://doi.org/10.1007/s00270-014-0872-7.

    Article  PubMed  Google Scholar 

  40. Lüdemann L, Wybranski C, Seidensticker M, Mohnike K, Kropf S, Wust P, Ricke J. In vivo assessment of catheter positioning accuracy and prolonged irradiation time on liver tolerance dose after single-fraction 192Ir high-dose-rate brachytherapy. Radiat Oncol. 2011; 6(1). https://doi.org/10.1186/1748-717X-6-107.

  41. Gargett M, Haddad C, Kneebone A, Booth JT, Hardcastle N. Clinical impact of removing respiratory motion during liver SABR. Radiat Oncol. 2019; 14(1). https://doi.org/10.1186/s13014-019-1300-6.

  42. Hu Y, Zhou YK, Chen YX, Zeng ZC. Magnitude and influencing factors of respiration-induced liver motion during abdominal compression in patients with intrahepatic tumors. Radiat Oncol. 2017; 12(1). https://doi.org/10.1186/s13014-016-0762-z.

  43. Tsai YL, Wu CJ, Shaw S, Yu PC, Nien HH, Lui LT. Quantitative analysis of respiration-induced motion of each liver segment with helical computed tomography and 4-dimensional computed tomography. Radiat Oncol. 2018; 13(1):59. https://doi.org/10.1186/s13014-018-1007-0.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This work was supported by the DFG’s Cluster of Excellence Munich-Centre for Advanced Photonics (MAP) and by the FöFoLe commission of the Medical Faculty of the LMU Munich under grant 1056.

Author information

Authors and Affiliations

Authors

Contributions

ASD evaluated the Monte Carlo simulations, performed the statistical analysis and drafted the manuscript. SC supervised the study, collected clinical data and helped to draft the manuscript. FK collected clinical data, reviewed the manuscript and helped to finalize it. KP reviewed the manuscript and helped to finalize it. FV supervised the study, reviewed the manuscript and helped to finalize it. GPF participated in the design of the study, supervised it, performed the Monte Carlo simulations and helped to draft the manuscript. GL participated in the design of the study, supervised it, and helped to draft the manuscript. MS, FS, FW, CK, JR and CB reviewed the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Guillaume Landry.

Ethics declarations

Ethics approval and consent to participate

This retrospective study was exempt from requiring ethics approval. Bavarian state law (Bayrisches Krankenhausgesetz/Bavarian Hospital Law §27 Absatz 4 Datenschutz (Dataprotection)) allows the use of patient data for research, provided that any person’s related data are kept anonymous. German radiation protection laws request a regular analysis of outcomes in the sense of quality control and assurance, thus in the case of purely retrospective studies no additional ethical approval is needed under German law.

Consent for publication

Not applicable.

Competing interests

The Department of Radiation Oncology of the University Hospital of the LMU Munich has an ongoing brachytherapy research agreement with Elekta, Inc.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary information

Additional file 1

Supplementary material.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Duque, A.S., Corradini, S., Kamp, F. et al. The dosimetric impact of replacing the TG-43 algorithm by model based dose calculation for liver brachytherapy. Radiat Oncol 15, 60 (2020). https://doi.org/10.1186/s13014-020-01492-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13014-020-01492-9

Keywords