Skip to main content

Table 3 Evaluations of dose distributions of PTV

From: Optimization of dose distributions of target volumes and organs at risk during stereotactic body radiation therapy for pancreatic cancer with dose-limiting auto-shells

 

Group

P-value (ANOVA)

P-value (LSD, 3-shell vs 5-shell)

P-value (LSD, 5-shell vs 7-shell)

P-value (LSD, 3-shell vs 7-shell)

Parameter

3-shell

5-shell

7-shell

CI

1.12 ± 0.05

1.10 ± 0.04

1.09 ± 0.03

< 0.001

<  0.001

0.024

<  0.001

nCI

1.21 ± 0.04

1.19 ± 0.03

1.18 ± 0.03

< 0.001

<  0.001

0.185

<  0.001

HI

1.44 ± 0.01

1.44 ± 0.01

1.44 ± 0.01

1.0

1.0

1.0

1.0

GI

3.03 ± 0.14

3.09 ± 0.13

3.07 ± 0.14

0.012

0.004

0.368

0.037

Coverage (%)

92.63 ± 2.22

92.60 ± 1.83

91.79 ± 1.44

0.016

0.904

0.014

0.010

100%_PD (cc)

38.92 ± 12.31

38.45 ± 12.85

37.73 ± 12.62

< 0.001

0.036

0.002

<  0.001

50%_PD (cc)

117.48 ± 35.83

117.65 ± 36.53

115.09 ± 36.84

< 0.001

0.749

<  0.001

<  0.001

30%_PD (cc)

344.53 ± 119.93

312.90 ± 110.18

299.15 ± 106.41

< 0.001

<  0.001

0.006

<  0.001

MU

54,674.51 ± 13,149.78

54,649.06 ± 13,246.72

54,058.67 ± 12,744.23

0.018

0.914

0.016

0.012