Skip to main content

Correction to: Improved plan quality with automated radiotherapy planning for whole brain with hippocampus sparing: a comparison to the RTOG 0933 trial

The Original Article was published on 02 October 2017

Correction

In the original publication [1] figure legends 2 and 4 have been swapped (Additional file 1 and Additional file 2). The original article was updated to rectify this error. The corrected figures are included to this Erratum.

Figure 2 Dose in close proximity to the hippocampus. Abbreviations: Dmin: Minimal dose, Dmean: Mean dose, Dmax: Maximal dose

Figure 4 Dose distribution in axial, coronal and sagittal view for a patient planned with HS WBRT with 10 × 3 Gy

Reference

  1. Krayenbuehl J. Improved plan quality with automated radiotherapy planning for whole brain with hippocampus sparing: a comparison to the RTOG 0933 trial. Radiat Oncol 2017 12:161 https://doi.org/10.1186/s13014-017-0896-7

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. Krayenbuehl.

Additional information

The original article can be found online at https://doi.org/10.1186/s13014-017-0896-7.

Additional files

Additional file 1:

Dose in close proximity to the hippocampus. Abbreviations: Dmin: minimal dose, Dmean: mean dose, Dmax: maximal dose. (JPG 35 kb)

Additional file 2:

Dose distribution in axial, coronal and sagittal view for a patient planned with HS WBRT with 10 x 3 Gy. (146 kb)

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Krayenbuehl, J., Di Martino, M., Guckenberger, M. et al. Correction to: Improved plan quality with automated radiotherapy planning for whole brain with hippocampus sparing: a comparison to the RTOG 0933 trial. Radiat Oncol 12, 173 (2017). https://doi.org/10.1186/s13014-017-0901-1

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/s13014-017-0901-1