Skip to main content

Table 1 Volume comparison

From: A deep image-to-image network organ segmentation algorithm for radiation treatment planning: principles and evaluation

 

Bladder

mean ± SD

Rectum

mean ± SD

Heart

mean ± SD

Lung left

mean ± SD

Lung right

mean ± SD

Volume MAN [ml]

331 ± 178

89 ± 39

569 ± 115

1,897 ± 604

2,220 ± 647

Volume AUTO [ml]

362 ± 209

97 ± 44

557 ± 108

1,914 ± 623

2,240 ± 668

Difference (MAN-AUTO) [ml]

32 ± 74

8.1 ± 22

11 ± 54

17 ± 158

19 ± 151

Ratio (MAN/AUTO)

0.9 ± 0.2

0.9 ± 0.2

1.0 ± 0.1

1.0 ± 0.1

1.0 ± 0.1

  1. Volume comparison between manual (MAN) and automatic contours (AUTO), mean values ± standard deviation