Table 5 Literature review of hypofractionated stereotactic studies

From: Brain metastases treated with hypofractionated stereotactic radiotherapy: 8 years experience after Cyberknife installation

Publication

date

Nb

pts/BM

Median Volume (cc) or size (mm)

Regimen

Isodose (%)

WBRT (%)

LC at 12 m (%)

Median OS

at 12 m (%)

RN (%)

Prognostic factors

Matsuyama et al. 2005–2009

299/573

8.6 mm (2.8–47.4)

Variable regimen

NC

10

94

57,8

2

Size

LIiang-hua et al. 2001–2011

171/354

14.3 cc (0.16–86)

4 × 8 Gy

80–90

68

68

51

6

WBRT for OS

Martens et al. 2006–2010

75/108

1 cc (0.1–29.2)

6Gyx5

6-7x5gy

7-10 × 4 Gy

NC

52

52

35

1

Volume

Giubilei et al. 2001–2006

30/44

4.8 cc (0.4–24.3)

3 × 6 Gy

4 × 8 Gy

Isocenter

100

86

36

0

NC

Marchetti et al. 2001–2005

65/81

8 cc (0.3–48.2)

3 × 8 Gy

80

44

58

25

1

NC

Fahrig et al. 2000–2005

150/228

30 mm

5 × 6-7Gy

10x4Gy

7 × 5 Gy

NC

34

NC

66

NC

Dose volume

Jiang et al. 2003–2009

40/NC

30 mm (3.1–5.5)

17,5 cc (6–64.6)

4 × 10 gy

90

25

94.2

55.3

2.5

Histology KPS

Scorsettiet al. 2004–2007

78/113

3.3 cc (0.1–28)

6x4Gy

7x5Gy

1 × 20 Gy

80

10

69

NC

NC

RPA

Nagai et al. 2009–2013

54/128

1.9 cc (0.1–18)

4 × 7 Gy

80

NC

91

52

0

NC

Fokas et al. 2012

214/214

30 mm

7 × 5 Gy

4x10Gy

Isocenter

0

90

31

NC

RPA

Ernst et al. 2003–2005

51/72

3 cc

5 × 7 Gy

5 × 6 Gy

NC

NC

NC

NC

NC

V4 < 20 cc

Inoue et al. 2010–2014

88/92

10 -74 cc

3 × 9 Gy

3x10Gy

57

0

90

NC

0

V14

RN

  1. LC local control, V14 Irradiated volume receiving 14 Gy, RN Radionecrosis, RPA Recursive Patitioning Analysis, m months, Vol Volume, NC not communicated, pts. patients, Nb Number