Skip to main content

Table 10 Percentage of lateral dose points passing the three Γ-criteria for varying histories at an initial beam energy of 10.7 MeV

From: Linac photon beam fine-tuning in PRIMO using the gamma-index analysis toolkit

Number of Histories (106)Average Dose Uncertainty (%)3 % /3mm (%)2 % /2mm (%)1 % /1mm (%)
512.499.485.162.1
109.198.885.154.0
255.9100.0100.074.5
65.063.7100.090.755.9