Table 10 Percentage of lateral dose points passing the three Γ-criteria for varying histories at an initial beam energy of 10.7 MeV

From: Linac photon beam fine-tuning in PRIMO using the gamma-index analysis toolkit

Number of Histories (106)

Average Dose Uncertainty (%)

3 % /3mm (%)

2 % /2mm (%)

1 % /1mm (%)

5

12.4

99.4

85.1

62.1

10

9.1

98.8

85.1

54.0

25

5.9

100.0

100.0

74.5

65.06

3.7

100.0

90.7