Skip to main content

Table 3 Example of evaluation parameter set for case #1

From: Impact of beam configuration on VMAT plan quality for Pinnacle3Auto-Planning for head and neck cases

Structure

DVH Parameter

 

Dose Limit in relation to D95

Absolute Dose

Limit in Gy

PTV1

D95

 

± 2%

69,30

D98

>

0,95 D95

65,8

Dmin

>

0,9 D95

62,4

STD

<

3,3%

2,3

PTV2

D95

 

± 2%

66,00

D98

>

0,95 D95

62,7

Dmin

>

0,9 D95

59,4

STD

<

3,3%

2,2

PTV3

D95

>

± 2%

59,40

D98

>

0,95 D95

56,4

Dmin

<

0,9 D95

53,5

STD

<

3,3%

2,0

SpinalCanal

D 1cm3

<

 

45

BrainStem

D 1cm3

<

 

45

Left Parotid

D66

<

 

20

Dmean

<

 

26

Right Parotid

D66

<

 

20

Dmean

<

 

26

Larynx

D05

<

 

69

D05

<

 

45

Mandible

D05

<

 

69

D10

<

 

60

D50

<

 

52

Neck

Dmax

<

 

40

Left Lens

D05

<

 

9

Right Lens

D05

<

 

9

Left OpticNerve

D05

<

 

50

Right OpticNerve

D05

<

 

50

Chiasm

D05

<

 

50

Pituitary

D05

<

 

50

Left InnerEar

D05

<

 

30

Right InnerEar

D05

<

 

30

Outline

DMax

<

1,15 D95

79,7

  1. Definition of an evaluation parameter set for an integrated boost technique with three dose levels (PTV1, PTV2, PTV3). Requirements for target coverage and dose homogeneity are described by DVH parameters, relative and absolute dose limits scaled according to the prescription dose D95 of each PTV (top part). DVH parameters and absolute dose limits are listed for organs at risk (bottom part)
  2. DMin Minimum Dose, DMax Maximum Dose, DMean Mean Dose, STD Standard deviation, DX Volume X is covered by the dose value, PTV Planning target volume