Table 5 Structures and Objectives used for the RapidPlan models. The rest of the OAR (Lenses, Optic Nerves, Orbits, Optic Chiasm, Larynx, Parotids and Trachea) have only a Line (preferring target) objective with volume, dose and priority Generated

From: Effectiveness of Multi-Criteria Optimization-based Trade-Off exploration in combination with RapidPlan for head & neck radiotherapy planning

  Volume (%) Dose (cGy) Priority
PTV 1 – Upper 0 6800 110
PTV 1 – Upper 3 6700 110
PTV 1 – Lower 98 6350 110
PTV 1 – Lower 100 6250 110
PTVLR - Upper 1 6300 110
PTVLR - Upper 5 5700 110
PTVLR - Upper 50 5400 65
PTVLR - Lower 98 5300 110
PTVLR - Lower 100 5200 120
PRV Brainstem Upper 0 4500 150
PRV Brainstem - Line (preferring target) Generated Generated Generated
PRV Spinal cord - Upper 0 4500 150
PRV Spinal cord – Line (preferring target) Generated Generated Generated