Skip to main content

Table 2 HU average error values between deformed pCT and CBCT before and after HM for each patient with the mean and the standard deviation

From: Assessing the impact of choosing different deformable registration algorithms on cone-beam CT enhancement by histogram matching

Verr [HU]

Patient’s number

RR-MI

DR-NCC

DR-MI

DR-NMI

Before HM

After HM

Before HM

After HM

Before HM

After HM

Before HM

After HM

1

138.50

141.33

71.03

64.70

75.94

68.07

73.53

65.67

2

140.00

143.01

57.89

49.10

60.77

51.76

59.90

49.87

3

260.62

288.10

73.58

65.17

76.33

66.71

75.09

64.84

4

257.67

274.16

65.76

55.10

71.23

57.05

68.51

54.03

5

239.04

267.54

67.48

55.73

73.34

59.89

71.44

58.02

6

258.85

269.82

82.09

77.88

87.37

80.24

86.24

79.04

7

171.96

195.80

57.74

47.26

60.12

48.18

58.90

46.26

8

193.20

194.09

54.89

45.74

58.68

47.75

57.23

46.03

9

153.75

173.61

51.82

45.90

56.13

51.47

54.33

49.09

10

251.15

269.41

59.29

52.92

62.16

54.96

60.62

53.01

Mean

206.47

221.68

64.15

55.95

68.20

58.60

66.57

56.58

SD

52.21

57.97

9.50

10.43

10.12

10.35

10.06

10.51