From: Investigation of irradiated volume in linac-based brain hypo-fractionated stereotactic radiotherapy

Fig. 2

Investigation of number of targets, shape regularity and treatment technique. a and b are EXT-50 and BMP-50, respectively, versus total PTV for plans with 1 target (primary model) compared to plans with 2, 3, and >3 targets for SAHO. The first term in the equations is the factor FN by which the primary SAHO model is multiplied by to achieve the indicated curve. Individual data points are not shown for ease of interpretation. c EXT-50 versus PTV for plans with RI > 0.6 compared to plans with target RI < 0.6. d EXT-60 vs Total PTV for a subset of clinical plans re-planned using FAHE. The arrows point from the original SAHO plan to the re-plan FAHE plan