Table 2 Summary of the organ doses (mean ± standard deviation) of the KBRT and expert plans. All doses are normalized to dose that is prescribed to the target volume. The Wilcoxon test shows significantly lower bladder dose for the KBRT plans (at D30), as well as lower rectal dose (at D10 and D30) for the expert plans

From: Knowledge-based radiation therapy (KBRT) treatment planning versus planning by experts: validation of a KBRT algorithm for prostate cancer treatment planning

Organ volume [%]

Bladder

Rectum

Mean organ dose of KBRT plans [%]

Mean organ dose of expert plans [%]

Mean organ dose difference (KBRT - expert)

Mean organ dose of KBRT plans [%]

Mean organ dose of expert plans [%]

Mean organ dose difference (KBRT- expert)

10

98.4 ± 4.4

98.3 ± 5.0

0.1 ± 2.9

93.0 ± 7.9

90.1 ± 9.5

3.0 ± 4.5

30

70 ± 25

74 ± 22

−3.0 ± 6.3

63 ± 17

57 ± 16

5.6 ± 8.1

50

44 ± 30

46 ± 29

−2.7 ± 9.1

39 ± 13

36.8 ± 9.9

2.4 ± 7.5

70

24 ± 22

24 ± 19

0.0 ± 7.1

24.6 ± 9.0

24.8 ± 7.1

−0.3 ± 5.4

90

11 ± 12

9.8 ± 8.7

1.0 ± 6.2

11.9 ± 6.2

12.6 ± 6.8

−0.7 ± 3.4