Skip to main content

Table 2 Comparison of the mean conformity index, homogeneity index, V 107% , PTV dose, and monitor units delivered per fraction for anteroposterior-posteroanterior (AP-PA) or butterfly intensity-modulated radiation therapy (IMRT) techniques

From: Dosimetric advantages of a “butterfly” technique for intensity-modulated radiation therapy for young female patients with mediastinal Hodgkin’s lymphoma

 

IMRT

AP-PA

Difference

P value*

RTOG Conformity Index (V100%/VPTV)

1.10

1.66

−0.56

0.37

RTOG Homogeneity Index (Imax/RI)

1.15

1.14

0.01

0.89

V107%, cm3

47.7

801.5

−753.8

0.01

PTV dose, Gy

31.39

32.02

−0.63

0.01

Monitor Units per Fraction

797

208

589

0.01

  1. Imax is the maximum isodose or maximum point dose. RI is the reference isodose or 30.6 Gy.