Skip to main content

Table 6 Dosimetric predictors for the development of vaginal ulcer

From: Vaginal tolerance of CT based image-guided high-dose rate interstitial brachytherapy for gynecological malignancies

   

2-y incidence ofvaginal ulcer (%)

 

Parameter

ROCAUC*

Cutoff

P value#

Vaginal wall D0.5cc|| (EQD2††)

0.667

≤195 Gy

0.0

0.058

  

>195 Gy

18.5

 

Vaginal wall D1cc|| (EQD2††)

0.682

≤171 Gy

4.2

0.091

  

>171 Gy

20.0

 

Vaginal wall D2cc|| (EQD2††)

0.733

≤145 Gy

3.7

0.026*

  

>145 Gy

23.5

 

Vaginal wall D4cc|| (EQD2††)

0.618

≤83 Gy

0.0

0.119

  

>83 Gy

15.6

 

Vaginal wall D6cc|| (EQD2††)

0.569

≤86 Gy

5.6

0.323

  

>86 Gy

15.4

 

Vaginal wall D8cc|| (EQD2††)

0.559

≤75 Gy

5.6

0.323

  

>75 Gy

15.4

 
  1. *AUC: area under the curve.
  2. ROC: receiver operator characteristic.
  3. ††EQD2: equivalent dose in 2 Gy fractions.
  4. ||D0.5cc, D1cc, D2cc, D4cc, D6cc, D8cc: most exposed 0.5, 1, 2, 4, 6, and 8 cm3 of tissue.
  5. Cutoff refers to the most predictive value from the AUC of ROC curve.
  6. # Univariate analysis by log-rank test.