Skip to main content

Table 1 Tumor location, inspiration and expiration durations, tumor volumes in EE phase, tumor motion between EI and EE phases, and in 3D

From: Evaluation and comparison of New 4DCT based strategies for proton treatment planning for lung tumors

Cases

Tumor location

Inspiration (seconds)

Expiration (seconds)

Tumor volume in EE phase (cc)

Motion (mm) between EI and EE phases

Tumor motion in 3D (mm)

     

Left-right

Superior-inferior

Anterior-posterior

 

A

Right upper lobe

1.6

0.5

0.4

1.5

3.2

1.3

2.2

B

Right upper lobe

1.7

2.4

1.3

3

3

2

2.7

C

Left upper lobe

1.5

1.5

2

1.1

6.3

4.0

4.4

D

Right upper/middle lobe

2

1.8

6.5

1.5

8

5.5

5.7

E

Right upper lobe

1.2

3.3

7.4

1.6

3.4

1.2

2.3

F

Right middle lobe

1.5

2.5

7.7

7.2

31.0

8.6

19.0

G

Left upper lobe

3.7

5.3

8.1

2.0

13

12

10.3

H

Left lower lobe

1.4

1.5

17.9

1.3

24.4

5.5

14.5

I

Left lower lobe

1.5

2.4

20.0

0.6

15.7

0.5

9.1

J

Left upper/lower lobe

2.3

2.3

25.7

2.1

10.7

6.3

7.3

K

Right upper lobe

1.7

2.1

69.8

4.3

5.1

7.4

5.8

L

Left upper/lower lobe

0.7

0.5

95.4

1.6

2.3

1.1

1.7