Skip to main content

Table 2 Dosimetric parameters of GTV and PTV planned by three different treatment techniques

From: Comparative analysis of dosimetric parameters of three different radiation techniques for patients with Graves’ ophthalmopathy treated with retro-orbital irradiation

Parameters (mean[range], Gy)

LOF

3DCRT

IMRT

GTV

   

 Minimum

5.03 [0.46-9.28]

7.30 [5.43-9.54]

9.85 [9.56-9.98]**,##

 Maximum

10.66 [10.58-10.86]

10.61 [10.55-10.68]

10.72 [10.52-11.03]

 Mean

10.09 [9.49-10.27]

10.30 [10.27-10.34]

10.32 [10.27-10.44]##

 Median

10.27 [10.11-10.36]

10.34 [10.30-10.37]

10.31 [10.27-10.44]

 D05

10.50 [10.37-10.59]

10.50 [10.46-10.54]

10.49 [10.41-10.69]

 D01

10.57 [10.47-10.73]

10.54 [10.50-10.60]

10.56 [10.45-10.80]

PTV

   

 Minimum

3.77 [0.35-7.95]

5.72 [3.98-8.53]

8.61 [6.85-9.53]**,##

 Maximum

10.67 [10.59-10.87]

10.61 [10.56-10.69]

10.76 [10.52-11.03]*

 Mean

9.86 [8.85-10.21]

10.19 [10.10-10.24]

10.26 [10.20-10.35]**,##

 Median

10.23 [10.07-10.58]

10.28 [10.20-10.32]

10.28 [10.23-10.39]

 D05

10.49 [10.39-10.59]

10.49 [10.45-10.53]

10.47 [10.40-10.67]

 D01

10.57 [10.49-10.72]

10.54 [10.50-10.61]

10.55 [10.44-10.78]

  1. * p<0.05, ** p<0.01 compared with 3DCRT.
  2. # p<0.05, ## p<0.01 compared with LOF.