Figure 2 | Radiation Oncology

Figure 2

From: A 4D IMRT planning method using deformable image registration to improve normal tissue sparing with contemporary delivery techniques

Figure 2

A phantom with tumor volume (shadow area) moving only in superior-inferior direction was illustrated to show how the non-uniform dose distribution was derived. The moving circle was divided into 4 phases (a), (b), (c), (d). The non-uniform prescribed dose distribution derived by the t4Dplan method was shown on (e) and its corresponding 4D dose was shown on (f) by summing the dose for 4 phases evaluated on (b). The prescribed dose for ITV approach (g) and the 4D dose (f). The non-uniform dose distribution acquired for t4Dplan with the total variation regulation from formula (5) was shown in (i) and its corresponding 4D dose (j).