Skip to main content

Table 1 Criteria for QA scores

From: Radiotherapy quality assurance review in a multi-center randomized trial of limited-disease small cell lung cancer: the Japan Clinical Oncology Group (JCOG) trial 0202

 

PP

DA

VU

GTV

   

   distance to field borders

1 – 3.5 cm

NA

< 1 cm or > 3.5 cm

   prescribed dose

45 Gy

Neither PP nor VU

< 40.5 Gy or > 49.5 Gy

ENI

   

   distance to field borders

1 – 3.5 cm

Neither PP nor VU

contralateral hilum included

   prescribed dose

27 – 36 Gy

NA

< 27 Gy or > 36 Gy

Overall treatment time

21 – 42 days

NA

> 42 days

Interfraction interval

≥ 5.5 hrs

4 – 5.5 hrs or <4 hrs (once)

< 4 hrs more than once

Organs at risk

   

   Spinal cord

≤ 36 Gy

Neither PP nor VU

> 39 Gy

   Lung

≤ 1/2 ipsilateral hemithorax

(≤ 2/3, upper lobe tumor) or

V20 ≤ 35%

Neither PP nor VU

> 1/2 ipsilateral hemithorax

(> 2/3, upper lobe tumor) or V20 > 40%

Heterogeneity correction

No

Yes (≤ 10% total dose difference)

Yes (> 10% total dose difference)

  1. Abbreviations: PP, per protocol; DA, deviation acceptable; VU, violation unacceptable; GTV, gross tumor volume; ENI, elective nodal irradiaton; NA, not applicable; hrs, hours; V20, percentage of the total lung minus PTV receiving ≥ 20 Gy.