Target Volumes |
---|
 | D min | D 95 | D max |
---|
PTV-1
| 56 Gy | 60 Gy | Â |
PTV-2
| 70 Gy | 74 Gy | 80 Gy |
Organs at risk
|
PTV-1 sine PTV-2
| Max 74 Gy to 5% | Max 66 Gy to 50% | Dmax 78 Gy |
Help contour ring 1.5 cm
| Max 60 Gy to 10% | Max 45 Gy to 50% | Â |
Bladder (BV)
| Max 70 Gy to 5% | Max 50 Gy to 20% | Max 30 Gy to 30% |
Rectal volume sine PTV
| Max 60 Gy to 5% | Max 40 Gy to 20% | Max 20 Gy to 40% |
Seminal vesicles
| Max 65 Gy to 20% | Â | Â |
- "PTV-1 sine PTV-2" is this proportion of the PTV-1 that does not overlap with PTV-2 – it is listed in organs-at-risk to limit doses >74 Gy to PTV-2. "Rectal volume sine PTV" is the portion of the rectum located outside PTV-1. These objectives were adjusted for the patient's anatomy to achieve optimal results. "Help contour ring" is a 15 mm wide ring shaped contour around the PTV-1 to confine high and mid doses to the target volume.