Skip to main content

Table 2 Dose volume constraints for anatomic planning and functional planning used for intensity-modulated radiotherapy (IMRT)

From: IMRT treatment plans and functional planning with functional lung imaging from 4D-CT for thoracic cancer patients

  

Anatomic planning

Functional planning

Structure

Constraint type

Dose

Volume (%)

Priority

Dose

Volume (%)

Priority

GTV

Maximum dose

105%

0%

50

105%

0%

50

Minimum dose

103%

100%

450

103%

100%

450

CTV

Maximum dose

105%

0%

400

105%

0%

400

Minimum dose

102%

100%

400

102%

100%

400

PTV

Maximum dose

105%

0%

650

105%

0%

650

Minimum dose

101%

100%

350

101%

100%

350

Total lung

Maximum dose

5 Gy

30%

200

5 Gy

30%

200

Maximum dose

10 Gy

25%

200

10 Gy

25%

200

Maximum dose

20 Gy

20%

200

20 Gy

20%

200

Functional lung

Maximum dose

   

5 Gy

30%

250

Maximum dose

   

10 Gy

25%

250

Maximum dose

   

20 Gy

20%

250

Spinal cord

Maximum dose

40 Gy

0%

300

40 Gy

0%

300

Spinal cord + 5 mm

Maximum dose

45 Gy

0%

300

45 Gy

0%

300