From: A technique for pediatric total skin electron irradiation
OSL Detector Location | AP + LPO + RPO Day 3 Dose (cGy) | PA + LAO + RAO Day 4 Dose (cGy) | Total Dose (cGy) | % Diff from Prescription |
---|---|---|---|---|
Forehead | 96.1 | 117.2 | 213.3 | 6.6 |
Posterior of Head | 121.9 | 84 | 205.9 | 3.0 |
Umbilicus | 79.1 | 117.3 | 196.3 | 18 |
Posterior of Umbilicus | 125.6 | 72.6 | 198.2 | 09 |
Back of Right Hand | 70.5 | 125.3 | 195.7 | 21 |
Average | 201.9 | 1.0 |