Table 4 Dose metric errors for different contours using dpCT-based dose distribution (%)

From: Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy

Category

Contours for comparison

Small Intestine

Rectum

Bladder

Spinal Cord

Femoral Head L

Femoral Head R

Bone Marrow

Dmean

D2

Dmean

D2

Dmean

D2

Dmean

D2

Dmean

D2

Dmean

D2

Dmean

D2

Smaller Diff(VCBCT,VpCT) (20 cases)

pCT contours vs. CBCT contours

1.443

8.166

0.687

3.907

0.314

3.400

4.972

2.659

1.957

3.446

2.064

3.559

0.744

1.540

 

dpCT contours vs. CBCT contours

1.379

9.440

0.417

2.102

0.290

2.809

3.527

2.607

1.579

2.986

1.452

3.253

0.568

1.234

 

sCT contours vs. CBCT contours

0.609

7.334

0.354

4.263

0.228

1.860

3.053

1.226

1.942

2.125

1.617

2.573

0.584

0.961

 

P* value

0.018

0.455

0.754

0.116

0.638

0.123

0.647

0.013

0.296

0.191

0.694

0.430

0.908

0.419

Larger Diff(VCBCT,VpCT) (20 cases)

pCT contours vs. CBCT contours

2.991

13.634

1.004

9.730

0.389

6.517

6.834

2.891

2.122

3.548

1.983

4.110

0.985

2.426

 

dpCT contours vs. CBCT contours

3.058

13.336

0.866

9.089

0.503

7.253

6.163

2.622

1.827

4.013

1.752

4.300

0.683

2.310

 

sCT contours vs. CBCT contours

0.714

6.629

0.404

4.766

0.862

3.039

5.130

1.280

1.933

2.067

1.809

3.226

0.566

2.209

 

P* value

0.001

 < 0.001

0.166

0.051

0.536

0.011

0.242

0.014

0.640

0.128

0.902

0.381

0.510

0.714

  1. *P was calculated by comparing the dose metric errors of the dpCT contours vs. CBCT contours and of the sCT contours vs. CBCT contours according to paired sample t tests
  2. \(Diff(V_{CBCT} ,V_{pCT} ) = \frac{{|V_{CBCT} - V_{pCT} |}}{{MIN(V_{CBCT} ,V_{pCT} )}} \times 100\%\)