Skip to main content

Table 1 Optimization objectives in the RapidPlan models

From: Knowledge-based DVH estimation and optimization for breast VMAT plans with and without avoidance sectors

Structure

Parameter type

Objective

Priority

PTV

Upper objective

Dmax,0% < 101% of prescription

95

Lower objective

Dmin,100% > 99% of prescription

95

Heart

Line objective

Generated

Generated

Lung_Homolat

Line objective

Generated

Generated

Lung_Contralat

Line objective

Generated

Generated

Breast_Contralat

Line objective

Generated

Generated