Skip to main content

Table 3 The average dosimetry results of PTV for 20 test patients. Seven dosimetry indexs, \({D}_{99\%}\), \({D}_{98\%}\), \({D}_{95\%}\), \({D}_{50\%}\), \({D}_{2\%}\), HI and CI, are included

From: Dose prediction for cervical cancer VMAT patients with a full-scale 3D-cGAN-based model and the comparison of different input data on the prediction results

Dosimetry indexes

Models

\({\varvec{D}}_{90\varvec{\%}}\)

\({\varvec{D}}_{98\varvec{\%}}\)

\({\varvec{D}}_{95\varvec{\%}}\)

\({\varvec{D}}_{50\varvec{\%}}\)

Predicted

Clinical

P-val

Predicted

Clinical

P-val

Predicted

Clinical

P-val

Predicted

Clinical

P-val

Model-A

53.4 ± 0.8

53.3 ± 0.6

0.596

54.2 ± 0.5

54.2 ± 0.4

0.449

55.1 ± 0.3

55.0 ± 0.3

0.104

57.0 ± 0.3

56.9 ± 4.0

0.061

Model-B

53.0 ± 0.9

0.108

54.0 ± 0.4

0.025

55.0 ± 0.3

0.683

57.3 ± 0.3

< 0.001

Model-C

50.6 ± 2.4

< 0.001

52.4 ± 1.7

< 0.001

54.3 ± 1.0

0.002

57.7 ± 0.3

< 0.001

Dosimetry indexes

Models

\({\varvec{D}}_{2\varvec{\%}}\)

HI

CI

Predicted

Clinical

P-val

Predicted

Clinical

P-val

Predicted

Clinical

P-val

Model-A

59.6 ± 0.7

58.5 ± 03

< 0.001

0.1 ± 0.0

0.1 ± 0.0

0.086

0.8 ± 0.0

0.8 ± 0.0

0.071

Model-B

59.6 ± 0.5

< 0.001

54.2 ± 1.4

0.073

0.8 ± 0.0

0.068

Model-C

60.0 ± 0.4

< 0.001

54.2 ± 1.4

< 0.001

0.6 ± 0.0

< 0.001

  1. The bold values denote that the difference of the dosimetry indexes between the predicted and clinical dose is not statistically significant
  2. Annotate: \({D}_{p}\) denotes the minimum dose received by volume in percentage of p; HI Homogeneity index; CI Conformity index