Skip to main content

Table 1 Organ at risk (OAR) dose constraints applied for 40 Gy per five fractions in pancreatic SBRT Pancreatic clinical tumor volume (CTV) and planning target volume (PTV) of > 95% of 40 Gy in five fractions. (PTV = CTV)

From: Effect of stomach size on organs at risk in pancreatic stereotactic body radiotherapy

OAR

D0.1 cc

D5.0 cc

D10.0 cc

V12 Gy

V21 Gy

V30 Gy

V40 Gy

Stomach

≤ 22 Gy

 

≤ 16 Gy

≤ 12 cc

≤ 5 cc

≤ 1 cc

 

Intestine

≤ 22 Gy

≤ 17 Gy

≤ 11 Gy

 

≤ 5 cc

≤ 1 cc

 

Pancreas

   

≤ 50%

  

> 95%

Liver

 

Mean dose < 15 Gy

     

Left kidney

 

Mean dose < 10 Gy

     

Right kidney

 

Mean dose < 10 Gy

     

Spinal cord

≤ 22 Gy

    

≤ 1 cc