Skip to main content

Table 4 Treatment and dosimetric parameters reported in selected studies comparing VMAT and DCAT SIMT SRS techniques for multiple brain metastases

From: Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems

Parameter

Current study

Gavaert et al. [22]

Hoffmaier et al. [23]

Ruggeri et al. [24]

Liu et al. [25]

No of patients

36

10

20

20

30

No of lesions

367

40

66

97

217

Median number of lesions for patient

9 (2–25)

 

3 (2–6)

5 (2–10)

7.5 (4–10)

Median SRS (dose/fraction)

20 Gy, SF

20 Gy, SF

19 Gy, SF

18–27 Gy, 1–3 fr

14–24 Gy, SF

Median PTV (cm3)

0.32 (0.17–1.18)

3.15 (0.14–24.61)

0.8 (0.1–11.9)

2 (0.1–18.6)

0.35 (0.014–17.73)

Median total PTV (cm3)

3.42 (0.61–9.37)

10.6 (0.6–28.66)

NR

9.6 (0.5–29)

7.05 (0.49–27.32)

PTV Dmax/D2%

< 135% of PD

< 125% of PD

< 125% of PD

< 150% of PD

< 175% of PD

PTV Dmin/D98%

> 98%

> 99.5%

> 98%

> 98%

NR

Mean target coverage

VMAT 99.1% ± 2.4%

DCAT 98.9 ± 2.9%

NR

NR

VMAT 98.2% ± 2.9%

DCAT 96.4 ± 3.5%

VMAT 96.9% ± 2.5%

DCAT 97.5 ± 2.3%

Median conformity index

VMAT 0.6 (0.46–0.85)

DCAT 0.75 (0.52–0.86)

VMAT 0.67 ± 0.16*

DCAT 0.65 ± 0.08*

VMAT 0.73 (0.38–0.88)

DCAT 0.75 (0.58–0.89)

VMAT 0.94 (0.85–1.00)*

DCAT 0.75 (0.4–0.96)*

VMAT 0.77 ± 0.12

DCAT 0.7 ± 0.1

Median gradient index

VMAT 5.61 (3.64–8.37)

DCAT 4.54 (3.45–7.13)

VMAT 7.1 ± 3.1*

DCAT 3.9 ± 1.4*

VMAT 7.17 (3.35–33.0)

DCAT 5.99 (3.5–15.73)

VMAT 4.17 (3.32–7.46)*

DCAT 4.31 (3.29–5.79)*

NR

Median brain dose

VMAT 2.74 (0.55 -5.85)

DCAT 2.37 (0.65–5.62)

NR

NR

VMAT 2.99 (0.76 -6.17)*

DCAT 3.22 (0.85–7.34)*

VMAT 2.76

DCAT 2.57

Median total V12Gy

VMAT 18.51 (2.2–62.3)

DCAT 13.65 (1.87–45.9)

VMAT 46.3 ± 35.9*

DCAT 36.3 ± 27.1*

VMAT 3.1 (0.5–13.9)

DCAT 2.1 (0.1–13.1)

VMAT 23.7 (1.7–86.6)*

DCAT 37.3 (3.2–157.5)*

VMAT 19.2

DCAT 23.7

  1. DCAT Dynamic Conformal Arc Therapy, VMAT Volumetric Target Volume, SIMT Single-isocenter multi-targets, SRS Stereotactic Radiosurgery, PTV Planning Target Volume, PTV D2% and D98% dose received by 2% and 98% of PTV, SF Single Fraction, V12 Gy doses of 12 Gy received by healthy brain (brain-gross tumor volume)
  2. *value are reported as mean