Skip to main content

Table 2 Summary of translational and rotational deviation of each positioning system for each type of CBCT

From: Evaluation of inter- and intra-fraction 6D motion for stereotactic body radiation therapy of spinal metastases: influence of treatment time

CBCT

Abosolute translational shifts (mm)

Mean (SD, Max)

Absolute rotational shifts (°)

Mean (SD, Max)

X (Lat.)

Y (Vert.)

Z (Long.)

Rx (Pitch)

Ry (Yaw)

Rz (Roll)

Pos_Old (179)

 CBCTpTT (60)

4.0 (3.7, 15.9)

2.4 (2.2, 9.5)

5.0 (5.5, 26.4)

0.8 (0.6, 2.2)

1.0 (0.7, 2.7)

0.9 (0.7, 2.7)

 CBCT12 + 23 (119)

0.9 (0.9,5.2)

0.6 (0.7, 4.1)

0.9 (1.5, 9.6)

0.2 (0.3, 2.5)

0.2 (0.3, 1.8)

0.2 (0.3, 2.2)

Pos_New (150)

 CBCTpTT (50)

3.1 (3.7, 22.0)

1.6 (1.3, 6.2)

3.6 (3.1, 10.9)

0.7 (0.6, 2.3)

0.9 (0.7, 2.0)

0.9 (0.7, 2.4)

 CBCT12 + 23 (100)

0.5 (0.5, 2.7)

0.6 (0.7, 4.7)

0.5 (0.5, 2.9)

0.2 (0.3, 1.3)

0.2 (0.3, 1.9)

0.2 (0.3, 1.9)