Skip to main content

Table 2 Distance to the closest organ at risk and prescription dose for each patient

From: Benefit of replanning in MR-guided online adaptive radiation therapy in the treatment of liver metastasis

Patient

Organ

Distance (edge PTV to OAR)

Prescription dose

A

Heart

0.1 cm

5 × 9 Gy @ 65%

B

Heart

0.2 cm

5 × 9 Gy @ 65%

C

Heart

0.6 cm

5 × 9 Gy @ 65%

D

Bowel

Overlap

5 × 5 Gy @ 65%

E

Bowel

2.5 cm

4 × 9 Gy @ 65%

F

Heart

4.5 cm

5 × 9 Gy @ 65%

G

Stomach

3.0 cm

5 × 9 Gy @ 65%

H

Heart

Overlap

5 × 9 Gy @ 65%

I

Heart

0.2 cm

5 × 8 Gy @ 65%

J

Heart

7.0 cm

5 × 9 Gy @ 65%

K

Bowel

8.0 cm

6 × 5 Gy @ 80%

L

Bowel

Overlap

5 × 9 Gy @ 65%

M

Bowel

3.0 cm

5 × 7 Gy @ 80%

N

Stomach

Overlap

5 × 6 Gy @ 65%

O

Heart

4.0 cm

5 × 9 Gy @ 65 %