Skip to main content

Table 3 OAR constraints from institutional policies of the 11 respondents of the survey. For 3 and 5 fraction SABR treatments

From: Survey of current practices from an international task force for gynecological stereotactic ablative radiotherapy

Dose constraints

Constraint for 3 fxs

Constraint for 5 fxs

OAR

De novo

De novo

reRT

Rectum

Dmax < 18–35 Gy

V60–90% < 10 - 24Gy

Dmax< 37.5 - 38Gy

D2cc < 38Gy

V25Gy < =10 cc

Dmax< 25 - 30Gy

D2cc < 32Gy

Bladder

Dmax: <  20–40 Gy

V60–90% < 12- 24Gy

Dmax< 37.5–42 Gy

V35Gy < 5%

Dmax< 25 - 30Gy

D2cc < 36Gy

Sigmoid

Dmax < 20–33 Gy

Dmax < 39 - 40Gy

V25Gy < 20 cc

D2cc < 32Gy

Dmax< 25Gy

Large Bowel

Dmax < 9–33 Gy

Dmax< 38–40 Gy

D2cc < 34Gy

V25Gy < 20 cc

Dmax< 25 - 30Gy

D2cc < 32Gy

Small Bowel

Dmax: 9–33 Gy

< 1 cc > 24Gy

V50% < 10Gy

Dmax< 35–39 Gy

V25Gy < 5 cc

Dmax< 15 - 25Gy

max

D2cc < 20Gy

Skin

V60–95% < 12 - 24Gy

  

Kidney

D200cc <16Gy

Dmax <15Gy

V50–90% < 10-14Gy

D200cc < 17.5Gy

mean < 10–11 Gy

V18Gy < 35%

mean < 10Gy