Skip to main content

Table 4 Comparison of the small bowel dose-volume and NTCP between prone and supine patients

From: Evaluation of small bowel motion and feasibility of using the peritoneal space to replace bowel loops for dose constraints during intensity-modulated radiotherapy for rectal cancer

Variable

Supine position

Prone position

T

p

V5 (cc)

361.0 ± 113.2

208.0 ± 62.0

3.73

0.003

V10 (cc)

262.4 ± 78.5

191.4 ± 58.2

3.64

0.003

V15 (cc)

176.6 ± 47.2

160.0 ± 51.1

1.84

0.092

V20 (cc)

139.2 ± 44.7

134.7 ± 49.6

0.24

0.811

V25 (cc)

112.8 ± 41.9

110.3 ± 45.0

−0.28

0.777

V30 (cc)

86.8 ± 38.6

76.6 ± 37.9

−0.28

0.779

V35 (cc)

67.5 ± 34.1

60.3 ± 32.4

−0.02

0.980

V40 (cc)

52.4 ± 29.2

47.5 ± 28.9

0.06

0.953

V45 (cc)

38.8 ± 24.7

36.6 ± 24.4

0.18

0.856

V50 (cc)

21.3 ± 20.4

23.0 ± 16.8

0.24

0.813

Dmax (cGy)

5341 ± 28

5341 ± 29

0.01

0.989

NTCPC (%)

4.9 ± 2.9

2.3 ± 1.6

2.14

0.055

NTCPA (%)

58.3 ± 7.1

55.7 ± 9.8

1.74

0.109