Skip to main content
Fig. 5 | Radiation Oncology

Fig. 5

From: Clinical implementation of MRI-based organs-at-risk auto-segmentation with convolutional networks for prostate radiotherapy

Fig. 5

Example of in-phase MRI after cropping along with segmentations (OARs) obtained with DeepMedic (contours) versus clinical segmentations (filled contours) in the transverse (left), coronal (centre) and sagittal (right) view for a patient in the test. For this patient, average performance was obtained in terms of DSC: 0.96, 0.86, 0.97 and 0.97 for bladder, rectum, and femurs, respectively. Note that DeepMedic also outputs CTV, but it was not considered for clinical evaluation

Back to article page