  With CPAP Median (SD) Without CPAP Median (SD)  
Lung Volume (cc) 1506 (348) 945 (220.5) p < .0001
Mean Lung Dose (both lungs) 6.68 Gy (5.8) 6.39 Gy (3.5) p = 0.42
Lung V5 26.3%(11.9) 25.9 (16.6) p = 0.87
Lung V10 15.9%(9.18) 16.4 (14.75) p = 0.41
Lung V20 11.3%(7.7) 11.74 (13.7) p = 0.22
Heart Volume (cc) 351.9 (84.97) 352.8 (122.6) p = 0.17
Mean Heart Dose 1.34 Gy (0.72) 2.45 Gy (1.9) p = .0075
Heart V2.5Gy 7.9%(10.2) 19.51% (12.12) p = .0022
Heart V10 15.88%(9.2) 16.4 (14.8) p = 0.41
  1. SD Standard deviation
  2. Vx connoted the volume of the organ receiving “x” dose