Table 2 HU and mass density ranges used in PRIMO and Acuros computations

From: MLC parameters from static fields to VMAT plans: an evaluation in a RT-dedicated MC environment (PRIMO)

Material

PRIMO HU range

PRIMO mass density range (g/cm3)

Acuros HU range

Acuros mass density range (g/cm3)

Air

− 1000, −  957

0, 0.0204

−1000, −  957

0, 0.0204

Lung

−957, −  400

0.0204, 0.594

−  967, −  374

0.0104, 0.624

Adipose Tissue

−  400, −  59

0.594, 0.969

−  434, 1

0.551, 1.001

Muscle, Skeletal

− 59, 88

0.969, 1.075

−59, 117

0.969, 1.093

Cartilage

88, 298

1.075, 1.199

57, 971

1.056, 1.600

Bone

298, 2832

1.199, 2.833

128, 2832

1.100, 2.830