Table 2 The 5-arc plan template for LINAC larynx SBRT planning

From: Benchmarking techniques for stereotactic body radiotherapy for early-stage glottic laryngeal cancer: LINAC-based non-coplanar VMAT vs. Cyberknife planning

Field Energy Gantry Rotation Collimator Angle Couch Angle
 Arc 1 6x 270° CW 179° 10° 10°
 Arc 2 6x 90° CCW 181° 350° 350°
 Arc 3 6x 330° CW 20° 10° 90°
 Arc 4 6x 330° CW 20° 10° 90°
 Arc 5 6x 179° CCW 181° 350°