Skip to main content

Table 2 Results of questionnaire

From: Driving developments in UK oesophageal radiotherapy through the SCOPE trials

Development

Use prior to respective trials

Use currently

Comments

Consensus protocol for target volume delineation

Not specifically assessed in questionnaire

100%

Prior to SCOPE 1 trial there was wide variation in practice across the UK [14]

Use of prospective dose constraints

Not specifically assessed in questionnaire

96%

In 88% of centres these are based on the corresponding SCOPE trial

3d conformal planning

29%

100%

Now replaced by IMRT in SCOPE 2

Stomach filling protocol

12.5%

50%

 

CBCT

66.7%

87.5%

 

4D CT

42%

71%

 

Use of type b algorithm

79.9%

83.3%

pre NeoSCOPEa

IMRT

75% [1]

79%

[1]12.5% only using for upper 1/3 pre SCOPE 2

  1. aOnly 14/36 (39%) benchmark cases in SCOPE 1 used a type be algorithm [12]