Skip to main content

Table 2 Comparison of dose to PTV for 4 planning treatment: PTV66, PTV FDG 70%, PTV F-miso, PTV FDG 42 Gy

From: FDG and FMISO PET-guided dose escalation with intensity-modulated radiotherapy in lung cancer

Scenario

Boost target volume

Mean doses (SE) to target volumes

 
  

PTV66

PTV FDG 70%

PTV FMISO

PTV FDG 42Gy

p value

Reference plan (66Gy)

 

62.3 (± 0.38)

66.5 (± 0.33)

66.1 (± 0.32)

66.1 (± 0.32)

NA

Scenario 2

FDG Hotspot

62.7 (± 0.4)

72.5 (± 0.25)

67.9 (± 0.49)

67.9 (± 0.52)

0.001

Scenario 3

Fmiso

62.6 (± 0.42)

70.4* (± 0.74)

72.2* (± 0.27)

69.5 (± 0.74)

0.001

Scenario 4

FDG per treatment

63.7 (± 0.36)

71.9* (± 0.61)

69.8 (± 0.61)

73.1* (± 0.3)

0.001

  1. Data in boldface is the reference dose by plan