Skip to main content

Table 3 Auto Planning setting list

From: Auto- versus human-driven plan in mediastinal Hodgkin lymphoma radiation treatment

Auto-planning Settings

Max Itaration

60

    

Engine Type

Biological

    

Tuning Balance

5%

    

Dose Fall-Off Margin

1.8 cm

    

Hot-Spot Maximum Goal

102%

    

Use Cold-Spot ROIs

YES

    

Target Optimization Goals

PTV

30 Gy

    

CTV

30 Gy

    

OARs Optimization Goals

ROI

Type

Dose (Gy)

Volume (%)

Priority

Compromise

Heart

Mean dose

3

 

Medium

Yes

Heart

Max DVH

7.7

50

Medium

Yes

Heart

Max DVH

15

33

Medium

Yes

Left Lung

Mean dose

5

 

Medium

Yes

Left Lung

Max DVH

5

15

Medium

Yes

Left Lung

Max DVH

10

12

Medium

Yes

Left Lung

Max DVH

20

10

Medium

Yes

Right Lung

Mean dose

5

 

Medium

Yes

Right Lung

Max DVH

5

15

Medium

Yes

Right Lung

Max DVH

10

12

Medium

Yes

Right Lung

Max DVH

20

10

Medium

Yes

Esophagus

Max DVH

28

50

Medium

Yes

Esophagus

Max DVH

30

50

Medium

Yes

Thyroid

Mean dose

20

 

Medium

Yes

Thyroid

Max DVH

18

50

Medium

Yes

Thyroid

Max DVH

25

33

Medium

Yes

Left Breast

Mean dose

0.3

 

High

No

Left Breast

Max DVH

2

4

High

No

Left Breast

Max DVH

5

2

High

No

Right Breast

Mean dose

0.3

 

High

No

Right Breast

Max DVH

2

4

High

No

Right Breast

Max DVH

5

2

High

No

Spinal Cord

Max dose

25

 

High

Yes

PRV Spinal Cord

Max dose

26

 

High

Yes

Ring PTV (+ 1.5 cm)

Max dose

15

 

High

Yes

Body-PTV-Ring PTV

Max dose

10

 

High

Yes

  1. Abbreviations: ROI Region of Interest, PTV planning Target Volume, CTV Clinical Target Volume, OARs Organs At Risk, DVH Dose Volume Histogram