Table 2 Planning Target Volume (PTV) and Organ-At-Risk dose-volume constraints for plan optimization and patients violating the required constraints when the Auto Plan best optimization objective list was applied

From: Auto- versus human-driven plan in mediastinal Hodgkin lymphoma radiation treatment

Structure

Parameter

Required Objective

Patient violating the requirements

AP-BF Training

AP-BF Validation

AP-ARC Validation

PTV

 

Dmean (Gy)

30

–

–

–

 

V95% (%)

95

–

–

–

 

V107% (%)

1

3,4

6,7,8

6,7

Breast

 

V4Gy (%)

50

–

–

–

 

V10Gy (%)

33

–

–

–

Lung-PTV

 

V5Gy (%)

50

–

–

–

 

V10Gy (%)

33

–

–

–

Thyroid-PTV

 

Dmean (Gy)

20

3

–

–

 

V18Gy (%)

50

3

–

–

 

V25Gy (%)

33

–

–

–

Heart-PTV

 

Dmean (Gy)

3

2

6,8

6,8

 

V7.7Gy(%)

50

–

–

–

 

V15Gy(%)

33

–

–

–

Spinal Cord

 

Dmax (Gy)

30

–

–

–

Esophagus-PTV

 

Dmax (Gy)

32

–

–

–