Skip to main content

Table 4 Dosimetric parameter comparison among a selected series of blockage modes using a semi-circular block

From: Efficacy of virtual block objects in reducing the lung dose in helical tomotherapy planning for cervical oesophageal cancer: a planning study

 

Non-block (control group)

Block 7 (D)

p

Block 8 (C)

p

Block 8 (D)

p

Lung

V5 (%)

48.0

29.2

<  0.001

26.4

<  0.001

31.3

<  0.001

V10 (%)

39.4

20.6

<  0.001

20.6

<  0.001

22.4

<  0.001

V20 (%)

16.0

12.1

0.002

13.3

0.046

13.2

0.028

VS5 (mL)

1747

2308

0.023

2454

0.004

2299

0.023

mean dose (Gy)

9.6

6.8

<  0.001

7.0

<  0.001

7.1

<  0.001

Conformity Index

0.85

0.77

0.012

0.79

0.131

0.82

0.616

Homogeneity Index

0.04

0.07

0.001

0.07

0.002

0.05

0.100

Spinal cord PRV max dose (Gy)

47.9

49.7

<  0.001

50.2

<  0.001

49.4

0.002

Body max dose (Gy)

63.3

64.7

0.005

65.2

<  0.001

63.9

0.317

Heart mean dose (Gy)

6.2

7.4

0.564

7.2

0.719

7.0

0.811

Thyroid mean dose (Gy)

53.6

54.0

0.964

55.4

0.315

54.0

0.968

Delivery time (min)

4.9

6.0

<  0.001

6.2

<  0.001

5.6

0.010

  1. V5 lung volume receiving 5 Gy, V10 lung volume receiving 10 Gy, V20 lung volume receiving 20 Gy, VS5 normal pulmonary volume of less than 5 Gy, C complete block mode, D directional block mode, PRV planning risk volume