Table 2 Dose volume objectives, deviations, and benchmark case results (data for 36 cases)

From: Quality assurance of the SCOPE 1 trial in oesophageal radiotherapy

Structure & Dose Volume Objective

Minor Deviation

Major Deviation

Range

Achieved

Number of

Deviations

Type a algorithm:

PTV V95% > 99.0%

PTV deviations were not pre-classified but reviewed individually

98.6–100.0%

4 deviations

(98.6, 98.8, 98.9, 98.9%)

Type a algorithm:

PTV point minimum dose >93.0%

86.5–96.5%

2 deviations

(86.5, 92.7%)

Type b algorithm:

PTV V95% > 99.0% - [0.4 x % PTVoverlap]

92.4–99.3%

no deviations

ICRU maximum dose <107%

120% > max > 107%

max >120%

103–108%

2 minor deviations

(108, 108%)

Heart V40Gy < 30.0%

50% > V40Gy > 30%

V40Gy > 50%

16.1–33.0%

1 minor deviation

(33.0)

Liver V30Gy < 60.0%

70% > V30Gy > 60%

V30Gy > 70%

0.0–4.2%

no deviations

Combined lung V20Gy < 25.0%

35% > V20Gy > 25%

V20Gy > 35%

20.4–33.5%

18 minor deviations

(6 of which >30%)

Spinal cord PRV D1cc < 40.0Gy

N/A

D1cc >40Gy

34.2–41.5Gy

2 major deviations

(40.1, 41.5)