Skip to main content

Table 2 Comparison of the ITV and tracking concept

From: Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer

Dp [Gy]

Median 3D ITV [Gy]

Median (prctiles) [Gy] 3D Tracking −3D ITV

p-value

 

Median 4D ITV [Gy]

Median (prctiles) [Gy] 4D Tracking −4D ITV

p-value

 

TV

 

GTV

D mean

38.00

0.94 (0.39 to 1.09)

< 0.05

 

38.08

0.27 (–0.16 to 0.55)

0.233

D max

41.55

0.01 (–0.13 to 0.04)

0.791

 

41.85

–0.27 (–0.98 to 0.14)

0.064

D min

24.59

0.75 (–0.07 to 1.98)

< 0.05

 

24.83

0.34 (0.19 to 2.00)

0.064

D 95

29.02

3.70 (1.19 to 5.51)

< 0.05

 

30.87

1.56 (0.65 to 2.43)

< 0.05

D 2

40.87

0.05 (–0.11 to 0.20)

0.677

 

41.25

-0.27 (-0.81 to -0.04)

< 0.05

D 98

26.20

3.45 (1.24 to 5.30)

< 0.05

 

27.78

1.73 (0.77 to 2.25)

< 0.05

  Bowel

 

D mean

4.42

–0.27 (–0.56 to –0.06)

0.092

 

5.01

–0.45 (–0.58 to –0.24)

< 0.05

D 0.1cc

26.87

–1.34 (-1.51 to –0.73)

< 0.05

 

26.20

–0.60 (–1.14 to 1.11)

0.791

  Duodenum

 

D mean

9.95

–1.13 (–1.53 to –0.93)

< 0.05

 

10.45

–1.30 (–1.59 to 0.62)

< 0.05

D 0.1cc

27.31

–0.43 (–0.82 to –0.03)

0.164

 

27.97

0.46 (–1.41 to 0.63)

0.910

  Stomach

 

D mean

3.34

–0.39 (–0.80 to –0.08)

< 0.05

 

3.38

–0.30 (–0.60 to –0.07)

< 0.05

D 0.1cc

23.57

–1.04 (–2.17 to –0.03)

< 0.05

 

22.62

–0.11 (–1.11 to 0.97)

0.791

  Liver

 

D mean

2.04

–0.17 (–0.37 to -0.12)

< 0.05

 

2.15

–0.18 (–0.35 to -0.07)

< 0.05

  Left Kidney

 

D mean

3.89

–0.21 (–0.60 to 0.18)

0.266

 

3.58

–0.29 (–0.60 to -0.15)

< 0.05

  Right Kidney

 

D mean

3.90

–0.24 (–0.46 to 0.16)

0.176

 

4.00

–0.40 (–0.57 to 0.12)

< 0.05

  Spinal Cord

 

D max

9.24

–0.31 (–1.10 to 0.47)

0.569

 

9.26

–0.37 (–1.55 to 0.56)

0.569

  1. Dp: Dose parameter, prctiles = (25-percentile, 75-percentile), Target volume (TV): (ITV concept); GTV (tumor tracking).
  2. Differences of the dose parameters for tumor volume and organs at risk after 3D and 4D dose calculation are given