Skip to main content

Table 3 Means and standard deviations of gamma analysis

From: Dosimetric evaluation of synthetic CT for magnetic resonance-only based radiotherapy planning of lung cancer

 

Nvol

1%/1 mm

2%/2 mm

3%/3 mm

small-sized

18

94.6 ± 4.6

99.2 ± 0.9

99.9 ± 0.2

medium-sized

13

95.1 ± 3.1

99.4 ± 0.7

99.9 ± 0.1

large-sized

12

95.5 ± 5.6

99.3 ± 1.8

99.9 ± 0.2

Near Spine

9

93.8 ± 4.8

99.2 ± 0.8

99.9 ± 0.1

Near Trachea

16

94.6 ± 4.3

99.2 ± 0.9

99.9 ± 0.2

Near Ribs

9

94.0 ± 5.3

99.0 ± 1.9

99.9 ± 0.2

Lung Apex

9

98.0 ± 1.5

99.8 ± 0.3

100.0 ± 0.1

Total

43

95.0 ± 4.4

99.3 ± 1.1

99.9 ± 0.1

  1. NVol Number of PTV volumes