Skip to main content

Table 1 Overall dose volume histogram parameters for OARs

From: Short-course PET based simultaneous integrated boost for locally advanced cervical cancer

 

Bladder

Rectum

Sigmoid

Bowel*

Plan/Param

V30Gy [%]

V45Gy [%]

D2cc [Gy]

V30Gy [%]

V45Gy [%]

D2cc [Gy]

V30Gy [%]

V45Gy [%]

D2cc [Gy]

V30Gy [cm3]

V45Gy [cm3]

D2cc [Gy]

VMAT

Stand.

81.3 ± 2.2

48.0 ± 2.2

51.2 ± 0.1

90.8 ± 1.5

72.1 ± 1.9

50.9 ± 0.1

96.0 ± 1.3

75.0 ± 4.4

51.0 ± 0.1

448 ± 56

218 ± 31

51.7 ± 0.1

SIB

83.5 ± 2.3

48.7 ± 2.3

51.9 ± 0.3

91.1 ± 1.5

73.1 ± 2.0

51.4 ± 0.2

96.6 ± 1.4

75.3 ± 4.4

51.1 ± 0.1

452 ± 59

220 ± 31

51.8 ± 0.2

IMPT

Stand.

60.1 ± 2.4

44.3 ± 2.3

51.0 ± 0.1

84.7 ± 1.7

70.3 ± 1.7

50.9 ± 0.1

87.7 ± 3.6

74.1 ± 4.0

50.8 ± 0.1

313 ± 44

206 ± 30

51.3 ± 0.1

SIB

60.8 ± 2.4

45.1 ± 2.3

51.2 ± 0.2

85.2 ± 1.7

71.0 ± 1.8

51.2 ± 0.2

88.2 ± 3.5

74.4 ± 4.0

50.9 ± 0.1

316 ± 45

208 ± 31

51.6 ± 0.3

  1. Dose volume histogram parameters comparing the overall treatment following the short-course concept to a standard fractionated schedule
  2. Values are mean ± standard deviation of the mean
  3. Abbreviations: Stand standard plan of 1.8Gy X 28, SIB sum of 10 fraction SIB and 18 fraction standard plan
  4. *Entire potential space within irradiated area,
  5. Significant pair wise difference between Stand and SIB parameter