Skip to main content

Table 2 Summary of dosimetric results for PTV

From: Chest wall desmoid tumours treated with definitive radiotherapy: a plan comparison of 3D conformal radiotherapy, intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy

Parameter

3DCRT

IMRT

VMAT

P value

3DCRT vs IMRT

3DCRT vs VMAT

IMRT vs VMAT

Minimum (Gy)

40.0 ± 8.8

32.5 ± 11.2

30.57 ± 13.5

0.028

0.037

0.508

Maximum (Gy)

63.8 ± 3.0

67.5 ± 8.9

63.9 ± 2.9

0.203

0.959

0.333

Mean (Gy)

58.2 ± 1.9

57.5 ± 2.0

57.1 ± 1.4

0.092

0.074

0.878

D5%(Gy)

61.6 ± 2.2

60.5 ± 3.0

60.3 ± 2.5

0.169

0.037

0.859

D95%(Gy)

55.3 ± 2.8

53.3 ± 2.8

50.0 ± 8.6

0.203

0.053

0.114

HI (D5 % -D95 % ; Gy)

6.27 ± 2.76

7.20 ± 4.60

10.25 ± 10.42

0.575

0.386

0.139

V95 % (%)

95.5 ± 3.2

92.2 ± 7.2

92.5 ± 5.6

0.333

0.139

0.799

CI

1.35 ± 0.2

1.03 ± 0.13

0.98 ± 0.14

0.005

0.005

0.445

MU

313 ± 112

1427 ± 532

570 ± 285

0.005

0.432

0.005

Beam on time (second)

206 ± 122

302 ± 86

366 ± 164

0.056

0.005

0.231

  1. CI Conformity index, defined as the ratio between the volume receiving at least 95 % of the prescribed dose and the volume of the PTV, HI Homogeneity index, defined as difference between the dose covering 5 % and dose covering 95 % of the PTV. P value determined using Wilcoxon matched pair rank sum test in SPSS