Skip to main content

Table 2 Dose constraints for target volumes and organs at risk

From: A prospective study of nomogram-based adaptation of prostate radiotherapy target volumes

Target volumes

Mandatory

Ideal

 PTV70 D98%

≥70.0 Gy

-

 PTV70 D1cc

≤77.0 Gy

≤74.9 Gy

 PTV61.6 D98%

≥61.6 Gy

-

 PTV50.4 D98%

≥50.4 Gy

-

 CTVP

≥70.0 Gy

-

 CTVSVI D99%

≥70.0 Gy

-

 CTVECE D99%

≥61.6 Gy

-

 CTVLN D99%

≥50.4 Gy

-

Organs at risk

  

 Rectum D15%

≤74.0 Gy

≤74.0 Gy

 Rectum D25%

≤69.0 Gy

≤60.0 Gy

 Rectum D35%

≤64.0 Gy

≤50.0 Gy

 Rectum D50%

≤59.0 Gy

≤40.0 Gy

 Bladder D15%

≤79.0 Gy

≤74.0 Gy

 Bladder D25%

≤74.0 Gy

≤60.0 Gy

 Bladder D30%

≤69.0 Gy

≤50.0 Gy

 Bladder D50%

≤64.0 Gy

≤40.0 Gy

 Neck of femur D5%

≤44.0 Gy

-

 Small bowel PRV D99%

≤52.0 Gy

-

 Small bowel V45Gy

≤195 cc

-

 Penile bulb mean dose

-

≤51.0 Gy