Skip to main content
Fig. 4 | Radiation Oncology

Fig. 4

From: Medically inoperable peripheral lung cancer treated with stereotactic body radiation therapy

Fig. 4

Comparing local control, disease free and overall survival rates in patients stratified by motion tracking system used during Cyberknife SBRT. Either a fiducial free (Xsight-spine/lung) or fiducial-based (Xsight-spine + fiducials) tracking system was used to localize and track tumors during each fraction of treatment. In the later technique, patients were initially aligned with Xsight-spine and then further adjusted through matching to intratumoral fiducials. a Overall Survival at 24 months was not statistically different in patients treated using Xsight-spine 69.2 % (95 % CL: 82.1-50.3 %) compared using Xsight-spine with fiducials 76.2 % (95 % CL: 88.6-58.0 %) (Logrank, p = 0.66) There was also no significant difference in b local control at 24 months for Xsight-spine alone 72.2 % (95 % CL: 94.8-49.6 %) vs. Xsight-spine with fiducials 52.3 % (95 % CL: 75.4-29.7 %) (Logrank, p = 0.44) or c disease free survival at 24 months when comparing Xsight-spine alone 51.4 % (95 % CL: 73.1-24.3 %) vs. Xsight-spine with fiducials, 52.3 % (95 % CL: 72.1-27.6 %) (Logrank, p = 0.97)

Back to article page