Table 1 A MONACO® planning template for prostate VMAT at the Universitätsmedizin Mannheim. P + SB = prostate and seminal vesicles

From: Knowledge-based radiation therapy (KBRT) treatment planning versus planning by experts: validation of a KBRT algorithm for prostate cancer treatment planning

Structure Cost function Reference dose (cGy) Isoconstraint
P + SB Target EUD   6000.0
  Quadratic overdose 6000.0 70.0
  Quadratic underdose 6000.0 70.0
Bladder Parallel 3000.0 40.0
  Serial   3500.0
Rectum Parallel 3000.0 30.0
  Quadratic overdose 3000.0 50.0
Patient Quadratic overdose 3500.0 120.0
  Quadratic overdose 2200.0 60.0
  Conformality   0.7