Skip to main content

Table 4 Residual errors (mm) of the upper vertebrae and clavicula (in parenthesis) when the orthogonal setup images are matched to different positions

From: Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold

 

Systematic error Σ

Random error σ

Margins in mm

Matching position

LAT direction

SI direction

LAT direction

SI direction

LAT direction

SI direction

MID_V

1.3 (2.5)

1.1 (2.3)

1.3 (2.2)

1.8 (3.1)

4.2 (7.8)

4.0 (7.9)

MID_R+UPPER _ST

1.9 (2.3)

3.0 (2.3)

1.3 (2.1)

2.3 (2.2)

5.7 (7.2)

9.1 (7.3)

MID_V+UPPER_ST

1.3 (2.5)

2.5 (2.4)

1.3 (2.2)

1.8 (2.4)

4.2 (7.8)

7.5 (7.7)

MID_V+MID_R

1.5 (2.3)

1.4 (2.0)

1.2 (2.0)

1.5 (2.3)

4.6 (7.2)

4.6 (6.6)

MID_V+UPPER_ST+MID_R

1.5 (2.3)

2.2 (2.0)

1.2 (2.0)

1.9 (2.2)

4.6 (7.2)

6.8 (6.5)

UPPER_ST

-

4.5 (3.4)

-

3.0 (3.0)

-

13.4 (10.6)

MID_R

-

2.4 (2.3)

-

2.4 (2.3)

-

7.7 (7.4)

Online match to optimal position1

1.7 (2.4)

3.5 (2.9)

1.4 (2.2)

2.9 (2.9)

5.3 (7.5)

10.8 (9.2)

  1. 1includes interobserver variation in image matching.