Table 1 Treatment techniques characteristics

From: Hodgkin’s lymphoma emerging radiation treatment techniques: trade-offs between late radio-induced toxicities and secondary malignant neoplasms

Technique- PTV i Fields or Subfields number Energy (MeV) Total MUs or protons per Gy Neutron equivalent dose (Sv)
AP-PA- PTV1 2 6 5040 0
AP-PA- PTV2 2 6 5038 0
AP-PA- PTV3 2 6 4157 0
FIMRT- PTV1 1 6 1427 0
3 15 2070 0.020
FIMRT- PTV2 1 6 1415 0
3 15 2040 0.020
FIMRT-PTV3 3 6 1714 0
3 15 2277 0.020
IMRT- PTV1 7 6 8020 0
IMRT- PTV2 7 6 9500 0
IMRT- PTV3 7 6 14000 0
TOMO- PTV1   6 10042 0
TOMO- PTV2   6 9661 0
TOMO- PTV3   6 8232 0
PROTONS- PTV1 1 88-170 5.43*1010 0.16
1 62-162 4.52*1010
PROTONS- PTV2 1 87-171 6.20*1010 0.19
1 62-162 4.52*1010
PROTONS- PTV3 1 88-180 3.52*1010 0.23
1 88–173 3.92*1010
1 62–162 3.42*1010
  1 62-166 3.34*1010